X - 25
Mowers
Tensioning the V-belts
Use the mounting lever (1) supplied in
the on-board tool box.
Use mounting lever (1) to raise idler pulley (2).
Place V-belt (3) onto pulley (4).
Lower idler pulley (2) slowly and withdraw mounting
lever (1).
With V-belt under tension dimension X
must be equal to approx. 5 mm.
Installing the guard
Install guard (1) onto mower (3) using the hex. head
bolts (2).
x
BMS01312
4
2
1
3
BMS01340
1
2
3
Also lock the outer clamping levers (1) and (2).
Be sure the clamping levers (1) and (2) are
under tension when being locked.
Retighten as required.
BMS01290
1
2