KRONE ISOBUS-Terminal CCI 100
128
Pos: 61.46.64 /Überschriften/Überschriften 2/A-E/Alarmmeldungen @ 19\mod_1238572457463_78.docx @ 221082 @ 2 @ 1
11.9 Alarm
messages
Pos: 61.46.65 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-EasyCut/EasyCut B 1000/AlarmmeldungenAllgemeine Alarmmeldungen Tabelle EC B 1000 (2014-10-14 16:17:34) @ 200\mod_1385454797389_78.docx @ 1682836 @ @ 1
No. Figure
Possible cause
Remedy
A0
1
–
The plug-in fuse in the job computer is
defective.
–
Short circuit on electrical outputs
+12V2FU_L
– Check the connection
for short circuit and
replace the fuse.
A0
2
A02
FUSE
12V Pow3
–
Fuse in the job computer defective
–
Short circuit on electrical outputs
+12V3FU_L
– Check the connection
for short circuit.
– The fuse resets itself
after the unit has cooled
down.
A0
4
A04
–
The connection to the multi-function lever is
interrupted.
–
The multi-function lever is not connected
properly.
– Check the wiring of the
multi-function lever.
A1
4
– Undervoltage
–
The tractor battery is defective.
–
The dynamo of the tractor is too low.
–
12V power supply is too weak on tractor side
or not correctly connected with the battery.
– Connect KRONE
connection cable
directly to the battery of
the tractor.
A1
5
– Overvoltage
–
The dynamo of the tractor is defective.
– Check dynamo.
A2
1
A21
PIC-I01
–
CAN connection is interrupted between job
computer and KRONE-PIC I/1 computer.
–
CAN wiring is defective.
–
KRONE-PIC-I01 computer is inactive.
– Check
CAN
wiring.
– Replace
KRONE-PIC-
I01 computer.
A2
2
A22
PIC-I02
–
CAN connection is interrupted between job
computer and KRONE-PIC I/2 computer.
–
CAN wiring is defective.
–
KRONE PIC-I02 computer is inactive.
– Check
CAN
wiring.
– Replace
KRONE-PIC-
I02 computer.
Pos: 61.46.66 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1