KRONE ISOBUS-Terminal CCI 100
129
Pos: 61.46.67 /Überschriften/Überschriften 3/K-O/Logische Alarme @ 185\mod_1379419186279_78.docx @ 1594483 @ 3 @ 1
11.9.1
Logical Alarms
Pos: 61.46.68 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-EasyCut/EasyCut B 1000/Alarmmeldungen/Logische Alarme EC B 1000 @ 190\mod_1381472757103_78.docx @ 1628094 @ @ 1
No. Image
Possible cause
Remedy
1
–
The P.T.O. shaft is still running
when attempting to move the
mowing unit left into transport
position.
–
Turn off P.T.O. shaft and wait
until it stops.
2
–
The P.T.O. shaft is still running
when attempting to move the
mowing unit right into transport
position.
3
–
Pressure threshold is not
reached.
–
The tractor engine is OFF.
–
The hydraulic block does not get
any oil.
–
Start the tractor engine.
–
Pressurise the control unit.
–
Check the LS hydraulic system.
4
–
The information appears when
folding up the machine into
transport position.
–
Observe transport height.
–
Make certain the side guards are
folded up.
5
–
The setpoint working width right
is not reached.
–
Check the parts for width shift for
damage.
–
Completely retract the lateral
mowing unit once.
6
–
The setpoint working width left is
not reached.
11
11
L
–
The swath roller height left is not
reached.
–
Check the parts for swath roller
height for damage.
12
12
R
–
The swath roller height right is
not reached.
13
13
L
–
Time error, the process for lifting
mowing unit left takes longer
than 30 seconds.
–
The sensor setting is incorrect.
–
Insufficient hydraulic supply.
–
Perform a sensor test.
–
Check hydraulic supply.
14
14
R
–
Time error, the process for lifting
the mowing unit right takes
longer than 30 seconds.
–
The sensor setting is incorrect.
–
Insufficient hydraulic supply.
15
15
–
Time error; the process for lifting
the front mowing unit takes
longer than 30 seconds.
–
The sensor setting is incorrect.
–
Insufficient hydraulic supply.