Special equipment
218
Pos: 120.30 /Überschriften/Überschriften 3/K-O/Ölkontrolle @ 0\mod_1197021908190_78.docx @ 16120 @ 3 @ 1
22.7.3
Checking the oil level
Pos: 120.31 /BA/Sonderausstatung/EasyCut / AM Mähwerke/Querförderer/Hydraulik Ölstandskontrolle Bild EC B 1000 CV Collect @ 101\mod_1330684489399_78.docx @ 899332 @ @ 1
Fig. 146
Pos: 120.32 /BA/Sonderausstatung/EasyCut / AM Mähwerke/Querförderer/Hydraulik-Ölstandskontrolle @ 10\mod_1222335584255_78.docx @ 140585 @ @ 1
Check the hydraulic oil level after every 10 operating hours of the cross conveyor.
To do this:
•
Lower the machine and switch off the engine.
•
Unscrew and remove the ventilation filter (2) (with measuring rod).
•
• Use a lint-free cloth to clean the ventilation filter (2) and insert it again completely.
•
Pull out the ventilation filter (2) again.
•
The oil level must lie between the min. and max. mark.
•
Top off with hydraulic oil if necessary.
•
Screw in and tighten the ventilation filter (2).
Pos: 120.33 /Überschriften/Überschriften 3/K-O/Ölwechsel @ 0\mod_1197021941955_78.docx @ 16139 @ 3 @ 1
22.7.4 Oil
change
Pos: 120.34 /BA/Sonderausstatung/EasyCut / AM Mähwerke/Querförderer/Hydraulik-Ölwechsel @ 10\mod_1222335966973_78.docx @ 140673 @ @ 1
Change the hydraulic oil every 500 hours (but at least once a year).
•
Unscrew and remove the ventilation filter (2) (with measuring rod).
•
Screw out the oil drain plug (3).
•
Collect the used oil in a suitable drip pan.
•
Screw in the oil drain plug (3).
•
Top up oil (2) (the oil level must lie between the min. and max. mark).
•
Screw in and tighten the ventilation filter (2).