10.11.1
Blade Screw Connection
Pos : 24.33. 25 / BA/ Wart ung/M ähwer ke/M ess erschr aub / M ess erschnellversc hlus s/Besc hr eibung M ess er wec hs el M ess erschr aubverschl uss @ 47\ mod_1285661949953_78. doc x @ 456898 @ 3 @ 1
EC-0-250
Pic. 35
•
Fold up safety device
•
Clean the area
•
Remove damaged or worn blades
•
To fit the blades, insert the blade (5) between the wear skid (2) and the cutting disc (1)
•
Insert the retaining bolt (3) from below through the wear skid, the blade and the cutting
disc
•
Place the locknut (4) on the retaining bolt from above and tighten it firmly (tightening
torque refer to chapter “Torques”)
•
Repeat the process for all blades
•
After fitting the blades, fold the safety device down again
Note
•
The cutter blades of anticlockwise rotating cutting discs / blade drums are different to
those of clockwise rotating ones. Make certain the direction of rotation is correct when
installing!
•
The arrow on the cutter blades must match the direction of rotation of the corresponding
cutting discs / blade drums
•
The locknut (4) used to secure the retaining bolts must not be used more than once
Order No. for clockwise rotating blade: 139-889
Order No. for anticlockwise rotating blade: 139-888