Maintenance - Blade Changing
68
Pos: 83.24 /Überschriften/Überschriften 3/K-O/Messerschraubverschluss @ 0\mod_1197270941296_78.docx @ 16578 @ 3 @ 1
14.2.1
Blade Screw Connection
Pos: 83.25 /BA/Wartung/Mähwerke/Messerschraub / Messerschnellverschluss/Beschreibung Messerwechsel Messerschraubverschluss @ 47\mod_1285661949953_78.docx @ 456898 @ @ 1
EC-0-250
Pic. 39
•
Fold up safety device
•
Clean the area
•
Remove damaged or worn blades
•
To fit the blades, insert the blade (5) between the wear skid (2) and the cutting disc (1)
•
Insert the retaining bolt (3) from below through the wear skid, the blade and the cutting disc
•
Place the locknut (4) on the retaining bolt from above and tighten it firmly (tightening torque
refer to chapter “Torques”)
•
Repeat the process for all blades
•
After fitting the blades, fold the safety device down again
Note
•
The cutter blades of anticlockwise rotating cutting discs / blade drums are different to those
of clockwise rotating ones. Make certain the direction of rotation is correct when installing!
•
The arrow on the cutter blades must match the direction of rotation of the corresponding
cutting discs / blade drums
•
The locknut (4) used to secure the retaining bolts must not be used more than once
Order No. for clockwise rotating blade: 139-889
Order No. for anticlockwise rotating blade: 139-888
Pos: 83.26 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Summary of Contents for EasyCut R 360