3.10 Display of the state of the device
After activating the power supply the device displays the current state of the device on the display
according to the operating mode and values of basic parameters of the heating/cooling system of
the building; see chapter 8.2.
Keys
and
allow moving up and
down the basic display.
READING ON THE DISPLAY
DESCRIPTION
Standby
Current state of operation.
Heating
►
2
35.5 °C
Set or calculated temperature of heating (only in
winter mode).
Return
32.3 °C
Current temperature of the return.
DHW
49.0 °C
Current temperature of DHW.
TD outside 88 7 °C
Current outside temperature.
TD60 in 12 days
Time left until the start of DHW thermal desinfection
(i.e. next thermal desinfection will begin in 12 days).
Setting of DHW thermal desinfection is controlled by
changing parameters
TD
and
HT every
described in
section 6 located in the main menu
DHW.
2016/02/10 12:24 TUESDAY
Current time and day of the week. Setting the time
and day of the week is described in section 5.9.
NOTE
No. 2 means the number of days until automatic mode switch.
No. 88 represents the activation delay time of the additional source in minutes.
The
symbol displays the activation of the electric heater.
3.11 Setting parameters
All parameter settings of the device’s operation and heating/cooling system of the building are set
as described below.
1.
For entering the user menu press the key
(MENU) on the basic display.
2.
The currently chosen menu is marked by the
symbols
> < (CHOOSE)
.
Keys
or
select the desired menu.
To enter the selected menu, press the
(ENTER) key.
For exiting the menus to the basic display press
the
(MENU) key.
The display shows only those menus which were
actually activated during the start-up of the
device!
Standby……………………………..
Heating
►
2
35.5°C
Return
32.3°C
DHW
49.0°C
Standby………………………………
Heating
35.5°C
Return
32.3°C
DHW
49.0°C
> Heating <
1. Circuit
2. Circuit
3. Circuit