6.3 BATTERY CHARGER CONFIGURATION
(
!
)
We recommend to call the assistance centre or
a technician if you have problems with the setting
given.
The machine is equipped with a
battery charger
configurated for OPTIMA maintenance free
battery
.
If the operator whish to use Pb-Acid battery or
GEL/AGM battery, it is necessary to change the
battery charger settings as follows:
(
!
)
DISPLAY OF THE BATTERY CHARGER SET-
TINGS
The battery charger settings are shown by the
blinking of the LED indicator when the battery
charger is switching on:
- the RED LED indicator ( Photo 17 -B )
flashes 2 times
= the battery charger is set for
PB-Acid
batteries
-
the GREEN LED indicator ( Photo 17 - C )
flashes 2 times
= the battery charger is set for
GEL/AGM or OPTIMA
batteries
The battery charger settings will be displayed even
if the battery is not connected.
(
!
)
DIP-SWITCH CONFIGURATION FOR CHARG-
ING CURVE SETTINGS FOR BATTERY CHARGER
CBHD1 12V 6A
To set the charging curve type for Pb-Acid,
GEL/AGM or OPTIMA batteries it is necessary to
operate on the dip-switches placed inside the
battery charger ( Photo 17 - D ) ( Photo 17 -
F )
.
To access the dip-switches it is necessary to remove
the lower panel of the battery charger ( Photo 17 -
A ); it is also possible to reach the dip-switches by
removing the plastic cap ( Photo 17 - E ).
To configurate the charging curve related to the dif-
ferent battery type it is necessary to set the dip-
switches as indicated in the Table A here below:
Table A
Photo 17
A) Battery charger cover
B) Red “LED” - Battery discharged
C) Green “LED” - Battery charged
D) Dip-Switches
E) Plastic cap
F) Dip-Switches for charging curve set-
ting