26
KH120CI
-
KH170CI
-
KH200CI
INSTALLATION
1) Carry the machine to the utilization place and lock every movement
using the parking brake (H).
2) Check that the oil level is always over the mark (L).
3) Connect the high pressure hose to the outlet connection (A) tightening
the metal ring completely, and the other end to the automatic gun (D).
4) Fill the diesel fuel into the appropriate tank from the mouth (E), the detergent
from the mouth (F) and the antilimestone from the mouth (G).
5) If the mains voltage corresponds (Volt/Hz ) to the indications on the
label fixed on the motor, you can plug the unit in (C).
It is prohibited to use extensions or loose plugs not to standards.
The electrical system the appliance is connected to must be made in
conformity with the laws in force in the country of installation.
It is recommended to have a differential thermomagnetic switch, with
sensitivity equal to 30 mA, upstream from the power socket.
6) Connect the water supply pipe (diameter not lower than 14 mm) to the
pump inlet connection (B).
Make sure that the suction filter of the suction hose connection is always
clean. The dirty filter causes a bad water supply and consequently a
bad pump operation with the inevitable risk of rapid wearing out and
breakage of internal mechanisms.
WARNING :
The earth connection is compulsory.
WARNING :
Diesel oil for vehicles only.
C
A
B
D
G
H
L
E
F