44
This dehumidifier can be used to control the relative humidity of a room. The machine works
on the principle of condensation. The lowest humidity content that can be achieved is
approx. 35 – 40 % relative humidity depending on temperature.
How it works
Moist air from the room is moved by a fan over a cold coil connected to the refrigeration
unit. The humidity condenses on the coil and drops down as water into the collector. The air
is then reheated by the condenser to its incoming temperature before being released back
into the room.
Transport ation and storage
The machine should whenever possible be transported in an upright position. If it is trans-
ported on its side, the machine must be placed in an upright position and left for at least
two hours before being connected to the mains and started. If the machine is not going to
be used for a significant period of time, the water tank, housing and coil must be cleaned
with a damp cloth and then rubbed dry before storage. The machine should then be packed
in its original box.
Installation
Position the machine on a level surface
Ensure that the air circulation in the room is sufficient
Do not obstruct the intake and outlet openings
Ensure a minimum distance of 20 cm to walls and furniture
Ensure a safe distance of 40 cm to flammable parts
Install the correct model for the correct size of max. room size: 300 m
3
The operating temperature is: +5 to +30 °C
What it is designed to do