INSTRUCTIONS
Transportation and storage
The machine should whenever possible
be transported in an upright position. If
it is transported on its side, the machine
must be placed in an upright position
and left for at least two hours before
being connected to the mains and
started.
If the machine is not going to be used
for a significant period of time, the water
tank and housing must be cleaned with
a damp cloth and then rubbed dry
before storage. The machine should then
be packed in its original box.
Installation
•
Position the machine on a level surface
•
Ensure that the air circulation in the
room is sufficient
•
Do not obstruct the intake and outlet
openings
•
Ensure a safe distance of 8 cm to
flammable parts
•
Ensure a minimum distance of 50 cm
to walls and furniture
•
Do not install in rooms larger than
60 m
3
•
Operating temperatures:
min. + 12
∞
C / max. + 30
∞
C
Starting the machine
•
Close doors and windows
•
Connect mains plug – power indicator
light (2) should go on
•
Check correct positioning of water
tank (7)
•
Set hygrostat controller (1) to desired
value
The machine works automatically, i.e. as
soon as the level of dryness set on the
controller is reached, the dehumidifier
switches off and only starts working
again when the humidity level rises. We
recommend that you fit a hygrometer in
the room in order to check the humidity
levels. If the humidity level is too high,
switch the hygrostat controller to a lower
value; if the humidity is too low, switch
the controller to a higher value. If you
set the hygrostat controller to 1, the
dehumidifier remains on permanently.
In the defrost phase – defrost light (4)
on – the compressor switches off,
although the fan continues to run.
Maintenance
When the water tank (7) is full, the unit
switches off automatically and the
middle indicator light (3) is illuminated.
•
Take hold of the tank by the grooves
on its left and right sides and carefully
remove it
•
Empty tank
•
Replace tank correctly
Direct water drainage
If required, the collected water can be
drained directly.
•
Remove water tank (7)
•
Remove the push-off plastic part from
the back of the machine
•
Insert hose (15 mm diameter –
available from normal outlets) through
the opening you have just made and
fit it over the outlet connector at the
top front left.
•
Place the other end of the hose in a
waste pipe ensuring that there is a
gradual downward slope. Make sure
that the water does not flow back into
the dehumidifier and that it can flow
freely through the hose.
•
Replace water tank.
Summary of Contents for AIRSEC 1400
Page 19: ......