ENGLISH
24
M1157-3_draft-0
• Rotate the two legs T, which are located on the rear-bottom
side of the frame, to make vertical the position of the dehu-
midifier.
• Make sure the dehumidifier fits completely on the rear brack-
et M.
Safety locking
Install the safety bracket R in the bottom side of the dehumidi-
fier. The bracket must be fixed to the wall and the structure of the
dehumidifier with the screws.
Pic.5 –
The safety bracket
Do not operate the dehumidifier without the safety
bracket. The safety bracket must be firmly screwed to
the dehumidifier and the wall.
The absence of the safety bracket may cause an ac-
cidental fall of the machine and cause damage, even
serious, to persons and property.
The exhaust pipe
For the drain connect a 14mm internal diameter rubber hose to
the connection D on the lower-left side of the frame.
Pic.6 –
The water drain
To ensure proper drainage of water make sure that
the drain hose is sloped and well laid out, with no
elbows or narrowing of any kind.
The control panel
Pic.7 –
The control panel
S1 - Green light ON
The green light indicates when the dehu-
midifier is operative, otherwise it blinks on status 0 (powered
but off).
S2 - Red light, full tank
The light blinks, together with the green
one S1, when the tank is full, missing or incorrectly positioned.
S3 - Yellow light, defrost
The light switches on during the auto-
matic defrosting cycle.
T1 - Decrease button
Pushing this button will decrease the val-
ue of the display D down to 0.
T2 - Increase button
Pushing this button will increase the value
of the display D up to C.
D - Display
The display shows the working state of the dehu-
midifier according to the table below (Tab.B). The value 0 means
OFF, from 1 to 9 means automatic functioning and is controlled
by the humidistat that switches the dehumidifier on or off if the
value of the relative humidity is higher or lower than the one
shown in Tab.B. The value C means ALWAYS ON and the dehu-
midifier works independently from the humidity value: never-
theless, any alarm has priority over the functioning mode.
Display
Functioning
0
Off
1 ÷ 2
from about 85% to 90% R.H.
3 ÷ 4
from about 70% to 80% U.R.
5 ÷ 6
from about 60% to 65% R.H.
7 ÷ 8
from about 45% to 55% R.H.
9
about to 40% R.H.
C
Continuous
Tab.B –
Functioning modes
Failures
The display is used by the electronic device to show particular
situations (Tab.C) If an error message is displayed please contact
your dealer for repair.
Display
Description
n
Temperature probe must be checked
u
Humidity probe must be checked
Tab.C –
Error messages
Summary of Contents for KRK 160
Page 2: ...2 M1157 3_draft 0 ...
Page 3: ...3 M1157 3_draft 0 ...
Page 4: ...4 M1157 3_draft 0 ...
Page 5: ...5 M1157 3_draft 0 ...
Page 11: ...11 M1157 3_draft 0 ...
Page 27: ...27 M1157 3_draft 0 ...
Page 28: ......