OPERATING INSTRUCTIONS
efuturo Wallbox
Maintenance plan
Carry out the following maintenance work at the specified intervals.
Maintenance interval every 6 months (half-yearly)
Part/component
Maintenance work
Housing
Visual inspection for defects or damage
Check device for secure mounting
Clean the housing from the outside with a damp cloth
Front cover
Visual inspection for defects or damage
Switching and safety devices
Visual inspection for defects or damage. Check the test button on the RCD
Maintenance interval every 4 years
In addition, carry out all maintenance work listed under „Maintenance interval every 6 months (half-yearly)“.
Part/component
Maintenance work
Cable connections and Plug-in
connectors
Check for firm attachment
Visual inspection for defects or damage
Charging station
Visual inspection for defects or damage
Check for function
System test
Perform system test
See „System test“ chapter
Troubleshooting
Danger
Fatal injury hazard due to improper maintenance/repair.
There is a danger of fatal injury to persons carrying out work for which they have neither been qualified nor instructed.
• The device is only allowed to be maintained/repaired by persons who are familiar with it, have been informed about
the dangers and possess the necessary qualifications
• Before maintenance/repair work is carried out, all safety conditions must be fulfilled
!
Danger
Fatal shock hazard!
Components are live. Touching live parts will result in electric shock, burns or death. Observe the following points
before working on the electrical system.
• Disconnect the device from the power supply
• Secure against switching back on
• Check freedom from voltage
• Grounding and short circuiting
• Cover adjacent live parts and secure the danger zone
!