KMPS-1-64 Manual
12/18
KM 8000 Rev. A
Page 6 of 40
Copyright © 2018 Kulite Semiconductor Products, Inc.
All Rights Reserved.
1.2
Part Numbers
The KMPS-1 part number is of the form:
KMPS-1-64-XX-Y-AA/BB/CC/DD
Where:
XX
– Purge Option
AP
– Air Purge Pneumatically activated purge block installed
NP
– No Purge
Y
– Communication Option
E
– Ethernet
R
– RS-485
AA
– Pressure range of first module (channels 0 - 15)
BB
– Pressure range of second module (channels 16 - 31)
CC
– Pressure range of third module (channels 32 - 47)
DD
– Pressure range of fourth module (channels 48 - 63)
If all ranges are the same then you can have just one pressure range indicated. If first two
modules are one pressure and second two are another than you can have just two pressure
ranges indicated. For all other orders all ranges must be specified. If all modules are
absolute or all are differential then it can be specified at then end but if they are different
then it must be specified for each module
Examples:
KMPS-1-64-AP-E-7BARD - 64 channels of 7 Bar differential with a purge and Ethernet
output
KMPS-1-64-AP-E-25D/50APSI - 32 channels of 25 PSI differential and 32 channels of 50
PSI absolute with a purge and Ethernet output
KMPS-1-64-NP-R-25/50/75/100PSIA -16 channels each of 25,50,75, and 100 PSIA with no
purge and RS-485 output.
KMPS-1-64-NP-R-100/50/XX/XXPSIA - 16 channels of 100 PSIA and 16 channels of 50
PSIA no modules in the last two positions. Please note that it is still a KMPS-1-64 not a
KMPS-1-32.
Summary of Contents for KMPS-1-64 Series
Page 1: ......