5 Installation/Dismantling
27 of 44
4STQ
2580.821/04-EN
4. Remove O-rings 412.54/.55/.56 from discharge cover 163 and, if necessary,
remove O-ring 412.58/.59 from the shaft sleeve 523 of the mechanical seal.
5. Take key 940 out of the keyway and store it.
6. Clean the pump components in the area of the mechanical seal, pump shaft 210,
discharge cover 163 and bearing bracket 330. Check for any damage.
Further dismantling of the mechanical seal is carried out at KSB.