Provide the personnel with protective equipment and make sure it is used.
▪
Contain leakages (e.g at the shaft seal) of hazardous fluids handled (e.g.
explosive, toxic, hot) so as to avoid any danger to persons and the environment.
Adhere to all relevant laws.
▪
Eliminate all electrical hazards. (In this respect refer to the applicable national
safety regulations and/or regulations issued by the local energy supply
companies.)
2.8
Safety information for maintenance, inspection and installation work
▪
Modifications or alterations of the pump are only permitted with the
manufacturer's prior consent.
▪
Use only original spare parts or parts authorised by the manufacturer. The use of
other parts can invalidate any liability of the manufacturer for consequential
damage.
▪
The operator ensures that all maintenance, inspection and installation work is
performed by authorised, qualified specialist personnel who are thoroughly
familiar with the manual.
▪
Carry out work on the pump (set) during standstill only.
▪
The pump casing must have cooled down to ambient temperature.
▪
Pump pressure must have been released and the pump must have been drained.
▪
When taking the pump set out of service always adhere to the procedure
described in the manual.
▪
Decontaminate pumps which handle fluids posing a health hazard.
▪
As soon as the work is complete, re-install and/or re-activate any safety-relevant
and protective devices. Before returning the product to service, observe all
instructions on commissioning. (
2.9
Unauthorised modes of operation
Never operate the pump (set) outside the limits stated in the data sheet and in this
manual.
The warranty relating to the operating reliability and safety of the supplied pump
(set) is only valid if the equipment is used in accordance with its intended use.
2.10
Explosion protection
Always observe the information on explosion protection given in this section when
operating an explosion-proof pump set.
Sections of the manual marked by the Ex symbol apply to explosion-proof pump sets
also when temporarily operated outside potentially explosive atmospheres.
Only pumps/pump sets marked as explosion-proof and identified as such in the data
sheet must be used in potentially explosive atmospheres.
Special conditions apply to the operation of explosion-proof pump sets in accordance
with EC Directive 94/9/EC (ATEX).
When operating explosion-proof pump sets, especially adhere to the additional
requirements marked by the Ex symbol.
The explosion-proof status of the pump set is only assured if the pump set is used in
accordance with its intended use.
Never operate the pump (set) outside the limits stated in the data sheet and on the
name plate.
Prevent impermissible modes of operation at all times.
2.10.1 Repair
Special regulations apply to repair work on explosion-proof pumps. Modifications or
alteration of the pump set may affect explosion protection and are only permitted
after consultation with the manufacturer.
!
DANGER
2 Safety
Amarex KRT
11 of 74