5 Installation at Site
22 of 72
Amarex N
Fastening the duckfoot bend with chemical anchors
Fig. 4:
Fastening the
duckfoot bend
1.
Position duckfoot bend 72-1 on the floor of the tank/sump.
2.
Insert chemical anchors 90-3.38.
3.
Bolt duckfoot bend 72-1 to the floor with chemical anchors 90-3.38.
t
=
h
re
q
t
fi
x
WAF
M
Hex. head WAF
do
l
Fig. 5:
Dimensions
Table 8:
Chemical anchor bolt dimensions
Bolt size
d
o
[mm]
t=h
req
[mm]
t
fix
[mm]
WAF
[mm]
M
[mm]
Hex.
head
WAF
[mm]
Torque
assy
[Nm]
M 10x130
12
90
20
17
10
7
20
M 16x190
18
125
35
24
16
12
60
Table 9:
Curing times of mortar cartridge
Floor temperature
Curing time
[min]
-5 °C to 0 °C
240
0 °C to +10 °C
45
+10 °C to +20 °C
20
> +20 °C
10
5.3.1.2 Connecting the piping
DANGER
Impermissible loads acting on the flange of the duckfoot bend
Danger to life from leakage of hot, toxic, corrosive or flammable fluids!
▷
Do not use the pump as an anchorage point for the piping.
▷
Anchor the pipelines in close proximity to the pump and connect them without
transmitting any stresses or strains.
▷
Observe the permissible flange loads.
▷
Take appropriate measures to compensate thermal expansion of the piping.
NOTE
When the pump set is used for draining low-level building areas, install a swing
check valve in the discharge line to avoid backflow from the sewer system.