5 Installation at Site
21 of 50
8417.8/20-EN
Table 5:
BOAX-SF – Dimensions [mm]
DN
EN 1092 PN 10 Type 11
EN 1092 PN 16 Type 11
a
Bolt size
a
Bolt size
Bolt/Nut
20
51,5
8 x M12 x 30
51,5
8 x M12 x 30
25
46,5
8 x M12 x 30
46,5
8 x M12 x 30
32
38,0
8 x M16 x 30
38,0
8 x M16 x 30
40
51,0
8 x M16 x 30
51,0
8 x M16 x 30
50
48,0
8 x M16 x 35
48,0
8 x M16 x 35
65
64,5
16 x M16 x 35
64,5
16 x M16 x 35
80
63,0
16 x M16 x 40
63,0
16 x M16 x 40
100
81,0
16 x M16 x 40
81,0
16 x M16 x 40
125
79,5
16 x M16 x 40
79,5
16 x M16 x 40
150
81,5
16 x M20 x 45
81,5
16 x M20 x 45
200
82,0
16 x M20 x 50
82,0
24 x M20 x 50
250
77,5
24 x M20 x 50
72,5
24 x M24 x 50
300
67,0
24 x M20 x 50
59,5
24 x M24 x 50
Threaded rods
350
90,0
32 x M20 x 55
82,5
32 x M24 x 60
400
100,5
32 x M24 x 60
93,0
32 x M27 x 70
450
105,5
40 x M24 x 60
93,0
40 x M27 x 70
500
108,0
40 x M24 x 60
85,5
40 x M30 x 80
600
107,0
40 x M27 x 70
77,0
40 x M33 x 90
When threaded rods or double-ended studs are used, at least 1 nut height must be added to the above bolt
lengths.
5.4.3 Dead-end service
Table 6:
Dead-end valve for all nominal sizes
Type series
Gases and liquids
2)
Liquids
Hazardous (Group 1)
Non-hazardous (Group
2)
Hazardous (Group 1)
Non-hazardous (Group
2)
BOAX-S/SF
Not permitted
Liners XU - K
≤ DN 200: ΔPS = 12 bar
max.
200 < DN ≤ 500: ΔPS =
7 bar max.
> DN 500: on request.
Liners XU - K
≤ DN 125: ΔPS = 12 bar
max.
> DN 125: ΔPS = 7 bar
max.
Liners XU - K
≤ DN 200: ΔPS = 12 bar
max.
> DN 200: ΔPS = 7 bar
max.
2
Liquids whose vaporisation pressure at the max. permissible temperature is at least 0.5 bar higher than the
normal atmospheric pressure (1013 mbar)
Summary of Contents for BOAX-B
Page 1: ...Butterfly Valve Installation Operating Manual ...
Page 49: ......