LCC
7
4.2 Designation
LCC-M 300-710.5M C M1
Pump Type l
Hydraulic Type l
Discharge Nozzle DN in mm l
Nominal Impeller Diameter in mm l
Mechanical Size l
Seal Type l
Options l
Material Code l
Hydraulic Type
M ............................................ Metal
R............................................. Elastomer
H............................................. Extra-Heavy Construction
Mechanical (Frame) Size
Seal Type
K ....................................... KE
B ....................................... Throat Bushing
M ....................................... Mechanical Seal
E ....................................... Expeller
Options
O ....................................... Open Shroud Impeller
A ....................................... Oil Lubricated
....................................... Grease Lubricated
T ....................................... Turn Down Impeller
U ....................................... Underwater Bearing Assembly
C ....................................... Elastomer Impeller
Nominal Flange and Impeller Diameters in mm (inches)
Designation Discharge
Suction Impeller
LCC 50 - 230
50
( 2” )
80
( 3” )
225
( 8.86” )
LCC 80 - 300
80
( 3” )
100
( 4” )
310
( 12.22”)
LCC 100 - 400
100
( 4” )
150
( 6” )
395
( 15.55”)
LCC 150 - 500
150
( 6” )
200
( 8” )
500
(
19.69”
)
LCC 200 - 610
200
( 8” )
250
( 10”)
610
( 24” )
LCC 250 - 660
250
( 10”)
300
( 12”)
660
( 26” )
LCC 300 - 710
300
( 12”)
350
( 14”)
710
( 27.95”)
4.3 Design
Details
Horizontal, end suction, modified volute casing pump with
three-vane impeller for large solids passage. Available in
interchangeable elastomer, metal and extra-heavy designs.
4.3.1 Pump
Casing
Three standard configurations are available:
1 Hard
Metal.
Single-wall casing, impeller and suction
liner of high-chrome white iron. Suitable for high-discharge
head, all particle sizes up to maximum sphere passage and
mildly corrosive slurries. Custom materials available for
highly corrosive slurries.
2 Elastomer Lined.
Radially split construction with ductile
iron outer casing and molded-elastomer inner liners.
Impeller of high chrome white iron or polyurethane. For
moderate discharge head, fine to medium particles and
highly corrosive slurries.
3
Extra Heavy Hard Metal.
Similar to hard metal version,
but with heavier sections and hydraulics suited to the most
severe slurry duties. Two-stage pressure capability.
Available in sizes LCC 150 - 500 and above.
All casings carry 125 pound, ANSI flange bolting patterns.
Adapters for conversion to DIN flanges are available.
Figure 4.3-1 LCC Hard Metal Wet End
Figure 4.3-2 LCC Elastomer-Lined Wet End
Figure 4.3-3 LCC Extra Heavy Hard Metal Wet End
4.3.2 Impeller
Form
All standard impellers are 3 vane, double shrouded designs
as seen in figures 4.3-1 through 4.3-3. Open-shrouded and
alternate vane number designs are available in some sizes.
4.3.3 Shaft
Seal
All standard pumps use replaceable gland packing in a
stuffing box with connections for flush water or sealing liquid.
Options include throat bushing, slurry duty mechanical seals
or expeller with grease lubricated gland packing.
1 2 3 4 5
35 mm
50 mm
70 mm
100 mm
125 mm
Summary of Contents for GIW LCC 100-400
Page 27: ...LCC 27 NOTES ...
Page 34: ......