TECHNICAL DATA

Voltage: 110 -230 VAC 50-60Hz

Frequency: 868 MHz

Operative range in open air: up to 150m

Inputs: Nr. 2

Outputs: Nr. 2 (5A 250V~AC - 5A 30VDC)

Operative range: -20 / + 55°C

Dimensions: 42 x 35 x 20 mm

Protection class: IP20

FUNCTIONS

STAND-ALONE

It is possible to manage relay outputs through 
the closure of the inputs present on auxi wls 
or using the opera remote commands previously
programmed.

LARES 4.0 CONTROL PANELS

Depending on its size, lares 4.0 control panels 
can manage up to 64 auxi wls. The activation 
of the outputs can be managed through 
scenarios or using the built-in inputs on auxi wls. 
Inputs present on auxi wls can work in different 
ways:
• 

Local

: no panel zone has to be associated to

   the input, in order to work in this mode. The
   2 inputs present on device could be used to 
   change the status of the outputs.

• As Panel zone

: in order to work in this mode, 

   a Panel zone has to be assigned to the input.
   The closure / opening of inputs is notified to 
   the Panel that will performs the programmed
   actions during the real time of the associated
   zone or its restoral.

Summary of Contents for auxi wls KSI2300002.300

Page 1: ...generally any load unreachable by cables auxi wls can be used in conjunction with lares 4 0 control panels or as a stand alone device In the second case the outputs can be controlled locally using th...

Page 2: ...ROL PANELS Depending on its size lares 4 0 control panels can manage up to 64 auxi wls The activation of the outputs can be managed through scenarios or using the built in inputs on auxi wls Inputs pr...

Page 3: ...CONTACTS STAND ALONE LARES 4 0 What follows is valid only for using auxi wls as stand alone device or as peripheral on Panel without associated zones see above In case of independent or interlocked ou...

Page 4: ...t or SPTD change over switch the ON time is re started Otherwise it turns off if the output is programmed as interlocked If the output is programmed as bistable it commutates at every press on the key...

Page 5: ...ipheral of the panel the led turns OFF Once the starting phase is over the led indicates the reception of a valid radio command 0 1 2 keys In case the outputs are programmed as independents a short pr...

Page 6: ...seconds The led on device stays lit to confirm the access on programming mode Hold the key i on remote command for 3 seconds in order to memorize it The led on auxi wls blinks 4 times to confirm the m...

Page 7: ...to confirm the configuration saving The monostable time is the time elapsed between the two press on key Long press on key 1 The led on auxi wls blinks 3 times to confirm the configuration saving Lon...

Page 8: ...rst power up These 3 blinks indicate the reset of factory data and auxi wls returns to the normal working mode In case the button is released before the end of procedure 3 blinks if the button is rele...

Reviews: