background image

code R30020.100en                                                                                                                                                                           www.kseniasecurity.com
ed.04/2020

OUTPUTS MANAGEMENT THROUGH OPERA REMOTE COMMANDS (STAND-ALONE)

What follows is valid only for using auxi wls as stand-alone device. To manage outputs with opera remote 
command it is necessary to enroll it. As explained in ‘Programming’ paragraph, each key of remote 
command can be associated with an auxi wls or 0-1-2 keys can be programmed to manage the relay outputs 
of 3 different auxi wls. To associate a single key of remote command to an auxi wls allows to manage up to 
3 auxi wls at the same time, with the same remote command, if these are covered by the RF channel. In case 
all the keys of opera remote command are associated to the same auxi wls, these operate as follows:

0   key

This key turns the 2 outputs in stay mode. This 
action is confirmed by turning on the central LED on 

opera

 remote command.

1   key

This key manages the first relay output. By pressing 
this key, the outputs react depending on the 
programming.
• If the output is programmed as 

monostable

 it be 

activated and remains active during the ON time. In 
case the output is already active and programmed 
as independent or SPTD (change over switch), the 
ON time is re-started. Otherwise it turns off, if the 
output is programmed as interlocked.
• If the output is programmed as 

bistable

, it 

commutates at every press on the key
To confirm the operation, opera remote command 
turns ON its left LED, if the outputs is activated and 
turns ON the central LED, if the output is 
deactivated.

2   key

This key manage the second relay output By 
pressing this key, the outputs react depending on 
the programming.
• If the output is programmed as 

monostable

 it be 

activated and remains active during the ON time. In 
case the output is already active and programmed 
as independent or SPTD (change over switch), the 
ON time is re-started. Otherwise it turns off, if the 
output is programmed as interlocked.
• If the output is programmed as 

bistable

, it 

commutates at every press on the key
To confirm the operation, opera remote command 
turns ON its left LED, if the outputs is activated and 
turns ON the central LED, if the output is 
deactivated.

i   key

This key allows to visualize the outputs status.
The short press on this key displays the status of the 
first output. If the output is active, the left LED of 
opera turns ON, otherwise it turns ON the central 
one. 
The long press on the same key (more than 3 
seconds) displays the status of the second output in 
the same way as the first one.

Summary of Contents for auxi wls KSI2300002.300

Page 1: ...generally any load unreachable by cables auxi wls can be used in conjunction with lares 4 0 control panels or as a stand alone device In the second case the outputs can be controlled locally using th...

Page 2: ...ROL PANELS Depending on its size lares 4 0 control panels can manage up to 64 auxi wls The activation of the outputs can be managed through scenarios or using the built in inputs on auxi wls Inputs pr...

Page 3: ...CONTACTS STAND ALONE LARES 4 0 What follows is valid only for using auxi wls as stand alone device or as peripheral on Panel without associated zones see above In case of independent or interlocked ou...

Page 4: ...t or SPTD change over switch the ON time is re started Otherwise it turns off if the output is programmed as interlocked If the output is programmed as bistable it commutates at every press on the key...

Page 5: ...ipheral of the panel the led turns OFF Once the starting phase is over the led indicates the reception of a valid radio command 0 1 2 keys In case the outputs are programmed as independents a short pr...

Page 6: ...seconds The led on device stays lit to confirm the access on programming mode Hold the key i on remote command for 3 seconds in order to memorize it The led on auxi wls blinks 4 times to confirm the m...

Page 7: ...to confirm the configuration saving The monostable time is the time elapsed between the two press on key Long press on key 1 The led on auxi wls blinks 3 times to confirm the configuration saving Lon...

Page 8: ...rst power up These 3 blinks indicate the reset of factory data and auxi wls returns to the normal working mode In case the button is released before the end of procedure 3 blinks if the button is rele...

Reviews: