3
EN
OUTPUTS MANAGEMENT THROUGH LOCAL CONTACTS (STAND-ALONE | LARES)
What follows is valid only for using
auxi wls
as stand-alone device
or as peripheral on Panel, without associated zones (
see above
).
In case of indipendent or interlocked outputs, the first input
manage the first relay output and the second input manage
the second relay output. In case of STPD (change over switch)
output it is possible to use one or another input to manage the
output. At the changing of the inputs status, outputs react as
follows:
•
MONOSTABLE OUTPUT
: If the input remains closed for less than a
second (
use with short pression of button
), the output is
activated during the ON time. In case the output is already
active, the ON time is restarted, if output is programmed as
indipendent or SPTD (
change over switch
). Otherwise the ON
time turns off, if the output is programmed as interlocked. If
the input remains closed for more than a second (
use with long
pression of button
), the output commutates both at the closure
and at the re-opening of the input.
•
BISTABLE OUTPUT
: If the input remains closed for less than a
second, the output commutates only at the input closure. If
the input remains closed for more than a second, the output
commutates both at the closure and at the re-opening of the
input
MONOSTABLE
MONOSTABLE
INDIPENDENT OR SPTD
MONOSTABLE
INTERLOCKED
BISTABLE
BISTABLE
< 1 sec.
> 1 sec.
ON time
ON time