background image

3

EN

OUTPUTS MANAGEMENT THROUGH LOCAL CONTACTS (STAND-ALONE | LARES)

What follows is valid only for using 

auxi wls

 as stand-alone device 

or as peripheral on Panel, without associated zones (

see above

). 

In  case  of  indipendent  or  interlocked  outputs,  the  first  input 

manage  the  first  relay  output  and  the  second  input  manage 

the second relay output. In case of STPD (change over switch) 

output it is possible to use one or another input to manage the 

output. At the changing of the inputs status, outputs react as 

follows:

• 

MONOSTABLE OUTPUT

: If the input remains closed for less than a 

  second (

use with short pression of button

), the output is 

  activated during the ON time. In case the output is already 

  active, the ON time is restarted, if output is programmed as 

  indipendent or SPTD (

change over switch

). Otherwise the ON 

  time turns off, if the output is programmed as interlocked. If 

  the input remains closed for more than a second (

use with long 

  pression of button

), the output commutates both at the closure 

  and at the re-opening of the input.

• 

BISTABLE OUTPUT

: If the input remains closed for less than a 

  second, the output commutates only at the input closure. If 

  the input remains closed for more than a second, the output 

  commutates both at the closure and at the re-opening of the 

 input

MONOSTABLE

MONOSTABLE

INDIPENDENT OR SPTD

MONOSTABLE

INTERLOCKED

BISTABLE

BISTABLE

< 1 sec.

> 1 sec.

ON time

ON time

Reviews: