INSTALLATION

ergo S (ergo M) keypads can be installed on any plain surface. Furthermore, on the back there are 3 easy-
open holes, suitable for DIN503 and for 60mm-screw-distance boxes.

STEP 1. OPENING

To open the keypad, please proceed as follows:
1. Push snap fingers (A) using a screw driver
2. Pull outward

STEP 2. WALL MOUNTING

1. Push the cable through to the opening (7)
2. Fix the keypad base to the wall-box with the supplied screws through the eyelets (1) and (3).
3. Drill and install a screw with a wall plug to perform the tamper function (4).
    For wall mounting the keypad, use suitable wall plug (not supplied) through the hols (1-3 or 1-2).

Legend

1.-3. Easy open hole to be opened to Built-In
         installation on DIN 530 box
1. -2. Eyelets for 60mm-screws-distance boxes
4. Place a wall mount screw to enable anti
    opening and removal tamper (4)
5. Remove the part and used to close the side hole
    (8). The hole is reserved for future use.
6. Speaker
7. Cable gland
8. Side hole (for future use)

Summary of Contents for ergo M

Page 1: ...tion of outputs terminals phone calls etc RFID Tag reading to arm and disarm the intrusion detection systems set up with the lares 4 0 devices Full Programming of system parameters Programming of loca...

Page 2: ...crophone Fast Addressing System no need to pre set the device address automatic recongnition from the control pannel lares 4 0 Accurate Temperature sensor future use Adjusting backlight and contrast P...

Page 3: ...pening 7 2 Fix the keypad base to the wall box with the supplied screws through the eyelets 1 and 3 3 Drill and install a screw with a wall plug to perform the tamper function 4 For wall mounting the...

Page 4: ...ty Second Line from the first character from the left the FW version loaded on the device x xx xxx from the 10th character the device serial number six numeric characters and at the 16th character S o...

Page 5: ...s Left or Right when keypad is in idle a sliding bar used for contrast adjustment will be enabled The ENTER key will store the new contrast value the ESC key will leave value unchanged Values will cha...

Page 6: ...G H I g h i 4 5 J K L j k l 5 6 M N O m n o 6 7 P Q R S p q r s 7 8 T U V t u v 8 9 W X Y Z w x y z 9 ESC KEY The ESC key allows to exit the current menu and go back to the previous level This means...

Page 7: ...t 0 5 seconds to scroll the menu or the configuration data available ergo S M this procedure is slower than the clockwise scrolling you can use with ergo S since it works at 0 5 seconds steps DOWN ARR...

Page 8: ...occurred with details Fault list list of faults in progress Zone status view of the status of the zones configured in the system Zone test list of zones that were never been in alarm since the TEST st...

Page 9: ...pressing ESC twice Then type the IP address in the browser address bar https control panel IP address Note The default address will be 192 168 2 97 in the event that the network to which the control p...

Page 10: ...rchased from them If used electrical or electronic equipment has batteries or accumulators these must be disposed of separately according to local provisions Correct disposal of this product guarantee...