FUNCTIONS
INSTALLATION
INSTALLATION ON A SWITCH BOX OR ON WALL - MOUNTED
INSTALLATION NOTES
• Display of system status
• Display of functioning parameters ( date/time, active GSM network, GSM level, etc)
• System commands (complete or partial arming, reset, activation of outputs terminals, phone calls, etc.)
• Full Programming of system parameters
• Programming of local parameters (audio volume, backlight levels and LCD contrast)
• Vocal messages recording
Ksenia ergo wls
can be installed on any plain surface. Furthermore, in the back ithen are 3 easy-open holes,
suitable for DIN503 and for 60mm-screw-distance boxes.
1. Push the cable through to the opening. ( fig. 1-7 )
2. Fix the keypad base to the wall - box with the supplied screws through the eyelets. ( fig.1-1,3 )
To wall mount the keypad, use proper plugs and screws (not supplied) through the eyelets.
( fig.1, 1-3 o 1-2 )
3. Use a plug and the apposite screw to enable tamper functionality (fig. 1-4 )
4. Connect the cables to the terminals on the rear of the keypad.
5. Close the keypad properly. (fig. 2-5)
1. At every new installation when
ergo wls
is switched on ( but not wire to bus ), the display
will show the following information:
• First line: “Ksenia Security”
• Second Line: from the first character from the left the FW version loaded on the device (x.xx.xxx),
as from the 10° character the device serial-number (six numeric characters).
And at the 16th character S or M depends on the model
MODES OF OPERATION (6) WIRED KEYPAD WITHOUT BATTERY
In mode 6 - wired keypad mode (display shows “ergo M only”),
In this configuration there is no battery to be used and the BUS cable
MUST
be wired directly to the terminal 1
fig. 2 (DESCRIPTION OF THE PARTS PCB).
Being wired BUS cable (
A + B -
) the keypad has all the ergo M keypad functionalities,
Warning! while using the keypad in mode 6 (ergo M only), all wireless functions are disabled.