background image

EN

5

INTRODUCTION

We are very glad for your purchase. The security barrier 

interdictio series, due to 

their small form factor, are particularly suitable for doors and windows protec-

tion; high quality materials and improved technology make these barriers ap

-

propriate also in outdoor. The 

interdictio

 barrier is managed by a Microprocessor 

Which control all the principal functions and handles the 

optical synchronism.

The software allows the barrier to work in 3 different ways, in practice summarize 

the various installation needs. 

Direct raysCrossed rays 

or 

AND

 function of two 

ADJACENT 

rays. with a screwdriver you make a short circuit between the two 

tinned points on

 receiver barrier, and you get in a quick and easy way, the 

desired operation. 
From factory the barriers are preprogrammed as follows.

2 to 4 Rays Mode 1 (1 Ray Alarm)
4 to 8 rays Mode 2 (2 Rays Alarm)

TECHNICAL DATA

Optical Range: 0,5 ÷ 4 m

Number rays for Alarm: 1 o 2 Adjacent

Nr. direct rays/cross: 2 … 8 / (4 ..22)

Minimum Distance to Intersection  0,5 m

Time spent: 120 o 240 mSec.

Recovery Time: 1 Sec.

Supply: 12 Volt (10÷16) Vcc - 30 mA (6 rays)

Barrier Outputs: N.C. ALARM (only Rx) e N.C. TAMPER

Contact range: 24 Vcc - 0.5 A

Operating Temperature Range: (-15/+60) °C

Protection grade: IP 44

Profile Dimensions: 17.5 x 14 mm (Width x Thickness)

Cover cap Dimensions: 100 x 24 x 20 mm. (L x W x H)

 17,5 mm

14 mm

 24 mm

 22 mm

 90 mm

500 - 100 0 - 1500 - 2000 - 2500 mm

Summary of Contents for Interdictio series

Page 1: ...trollo accessi Filtro Anti Switching Integrato Sincronismo Ottico Intelligente Doppie Ottiche per ogni Raggio Windows and Doors Security Protection Access control Integrate Anti Switching Filter Intelligent Optical Synchronism Double Optical for each Ray SECURITY BARRIER WITH IR RAYS INSTALLATION AND MAINTENANCE MANUAL ...

Page 2: ...I Mediante l uso di un cacciavite si effettua un CORTO tra 2 punti stagnati sulla Barriera RICEVENTE e si ottiene in modo semplice e veloce il funzionamento desiderato Da fabbrica le barriere sono PRE PROGRAMMATE come segue da 2 a 4 Raggi Modo 1 Allarme con 1 Raggio da 4 a 8 Raggi Modo 2 Allarme con 2 Raggi DATI TECNICI Portata ottica 0 5 4 Metri Numero raggi per allarme 1 o 2 Adiacenti Nr Raggi D...

Page 3: ...ITARE per 5 secondi JP2 2 I LED LAMPEGGIANO nella MODALITÀ impostata 3 Aprendo e Corto Circuitando si selezionano i MODI 1 2 o 3 4 Aprendo 5 secondi si ESCE dalla PROGRAMMAZIONE FUNZIONAMENTO Modalità di Funzionamento PRE IMPOSTATE sul Ricevitore Modo 1 LAMPEGGIO LED 1 SYNC Raggi Diretti Allarme con 1 Raggio T int 240 mSec Modo 2 LAMPEGGIO LED 2 ALLARME Raggi Diretti Allarme con 2 Raggi T int 120 ...

Page 4: ...ssa ritiene convenienti per miglioramenti tecnici o per qualsiasi altra esigenza di carattere costruttivo o commerciale L installazione di queste apparecchiature deve essere effettuata a regola d arte in accordo con le norme vigenti Queste apparecchiature sono state sviluppate secondo criteri di qualità affidabilità e prestazioni adottati dalla Ksenia Security Si raccomanda di verificare il corret...

Page 5: ... with a screwdriver you make a short circuit between the two tinned points on receiver barrier and you get in a quick and easy way the desired operation From factory the barriers are preprogrammed as follows 2 to 4 Rays Mode 1 1 Ray Alarm 4 to 8 rays Mode 2 2 Rays Alarm TECHNICAL DATA Optical Range 0 5 4 m Number rays for Alarm 1 o 2 Adjacent Nr direct rays cross 2 8 4 22 Minimum Distance to Inter...

Page 6: ... Mode 1 LED 1 SYNC FLASHING Direct rays Alarm with one Ray T int 240 mSec Mode 2 LED 2 ALARM FLASHING Direct rays Alarm with two Rays T int 120 mSec Mode 3 LEDs 1 2 FLASHINGS Crossed Rays Alarm with two Rays T int 120 mSec BARRIER RECEIVER Programming 1 Make a SHORT CIRCUIT with a screwdriver for 5 seconds JP2 2 The LEDs FLASHING in the Set MODE 3 MODES 1 2 3 are selected by opening and SHORT CIRC...

Page 7: ...ems must be carried out strictly in accordance with the instructions described in this manual and in compliance with the local laws and bylaws in force these devices have been designed and made with the highest standards of quality and performance adopted by Ksenia Security Is recommended that the installed system should be completely tested at least once a month Test procedures depends on the sys...

Page 8: ...er la maggior parte con fibre riciclate e materiali provenienti da fonti rinnovabili www kseniasecurity com ENVIRONMENTAL CARE The interdictio barrier has been specifically designed and manufactured for the environment respect as follows 1 No PVC 2 Halogen free laminates and lead free PCB 3 Low consumption 4 Packaging realized mainly with recycled fibers and materials RMX0300047 000 21 12 2017 CER...

Reviews: