- 15 -
Use the arrow keys to select the scraper bottom pause period, selection from 0 to 255sec.
After selection of the wanted period, press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.13 Transport screw ON
The transport screw conveying the fuel from the external fuel stock to the boiler will as a maximum run
during the time per filling inserted here. If the fuel sensor reports that the burner is full, before the ON
period has expired, the screw will stop according to the sensor signal.
TRANSPORT SC on
Press ”MENU”
TRANSPORT SC on
TRANSPORT SC
off
ADJUST 090 SEC
Use the arrow keys to select the max. running time for the transport screw, selection from 0 to 255sec.
After selection of the wanted period, press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.14 Transport screw OFF.
In order to prevent the transport screw from starting and stopping all the time, it is possible by means of
the OFF period to set the wanted intervals between starts.
Even if the OFF period has expired, the transport screw will not start if influenced by the fuel sensor.
TRANSPORT SC
off
Press ”MENU”
TRANSPORT SC off
SCREW STEP
0
ADJUST 008 MIN
Use the arrow keys to select the pause period for the transport screw, select from 0 to 255sec.
After selection of the wanted period, press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.15 Screw step 0.
The stokerscrew running period depends on the fuel and may be selected without limitation; as a starting
point, however, we recommend to use the values stated in the appendix at the end of this manual.
As for fine-tuning, please see the section ”Adjustment”.
SCREW STEP
0
Press ”MENU”
SCREW STEP 0
SCREW STEP
1
ADJUST 0.20 SEC
Use the arrow keys to select the stokerscrew running period, select from 0.3 to 52sec.
After selection of the wanted period, press ”MENU”, and your choice has been saved.
Summary of Contents for KSM-Multistoker 575-50
Page 3: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 61: ... 44 Supplement C ...
Page 62: ... 45 ...
Page 63: ... 46 ...
Page 64: ... 47 ...
Page 66: ......
Page 67: ......
Page 68: ......