CHARGING STAGES
Soft Charge
- When batteries suffer an over-discharge, the controller will softly ramps the battery
voltage up to 10V for 12V battery.
Bulk Charge
- Maximum current charging until batteries rise to Absorption level
Absorption Charge
-Constant voltage charging and battery is over 85%.
Equalisation Charge
- Only for WET battery or Calcium battery type, when the battery is deeply
drained below 10V (for 12V battery), it will automatically run this stage to bring the internal cells as an
equal states and fully complement the loss of capacity. (Gel and AGM battery do not run Equalization
charge)
Float Charge
- Battery is fully charged and maintained at a safe level. A fully charged battery has a
voltage of more than 13.6 Volts (for 12V battery).
OPERATION - L.E.D. INDICATION
Values are for 12V use.