background image

-13- 

2. Installation 

2.1 Unpacking 

Check that the following components have been included: 

z

 

Information CD 

z

 

The Media Converter unit 

z

 

DIN-rail mounting bracket (It may have been pre-installed on the device unit.) 

 
The following are available optional accessories: 

z

 

Plane Mounting Bracket: The bracket is used for mounting the converter on a plane surface. 

z

 

Commercial-rated AC power adapters:   
The adapters are used for supplying DC power to the converter via DC power jack interface. 

z

 

Industrial-rated power supply: The power can be used for supplying DC power to the converter via 
terminal block interface. 

Contact sales representative for the availability. 
 

Note: The operation temperature rating of the optional power adapters and power supply may differ from the 

rating of the media converters. 

 

2.2 Safety Cautions 

To reduce the risk of bodily injury, electrical shock, fire and damage to the product, observe the following 
precautions. 
 

z

 

Do not service any product except as explained in your system documentation. 

z

 

Opening or removing covers may expose you to electrical shock. 

z

 

Only a trained service technician should service components inside these compartments. 

z

 

If any of the following conditions occur, unplug the product from the electrical outlet and replace the part 
or contact your trained service provider: 

  - The power cable, extension cable, or plug is damaged. 

  - An object has fallen into the product. 

  - The product has been exposed to water. 

  - The product has been dropped or damaged. 

  - The product does not operate correctly when you follow the operating instructions. 

z

 

Do not push any objects into the openings of your system. Doing so can cause fire or electric shock by 
shorting out interior components. 

Summary of Contents for KFC-241

Page 1: ...KFC 241 Industrial 10 100BASE T to 100BASE FX Media Converters Installation Guide DOC 110516 1 ...

Page 2: ...es the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 269...

Page 3: ...bol CE indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class A EN 61000 6 3 2007 IEC 61000 6 3 2007 EN 55022 2006 A1 2007 CISPR 22 2005 Class A EN 61000 3 2 2006 IEC 61000 3 2 2005 EN 61000 3 3 2008 IEC 61000 3 3 2008 EN 55024 1998 A1 2001 A2 2003 CISPR 24 199...

Page 4: ...al Functions 11 2 Installation 13 2 1 Unpacking 13 2 2 Safety Cautions 13 2 3 DIN Rail Mounting 14 2 4 Mounting on a Plane Surface 18 2 5 Applying Power 21 2 6 Making Copper Port Connection 22 2 7 Making Fiber Port Connection 23 3 LED Indicators 24 3 1 States and Indications 24 Appendix On board Configuration 25 ...

Page 5: ...his function that allows to auto detect the twisted pair signals and adapts itself to form a valid MDI to MDI X connection with the remote connected device automatically FAR END FAULT FUNCTION The fiber port is facilitated with this function which conforms to IEEE 802 3u 100BASE FX specifications When the port detects a link failure on its receiving circuitry it will send out an FEFI Far End Fault...

Page 6: ...industrial enclosure z Screw plane mounting support for industrial enclosure z Industrial rated Emission and Immunity performance 1 1 Features z Convert speed and media type z Support full wire speed conversion z Support 10Mbps and 100Mbps speed on the copper connections z Auto MDI MDI X detection function on the copper port z Auto negotiation function on the copper port z Link fault pass through ...

Page 7: ...1 2 Specifications This figure shows the important components of the converters Model KFC 241 L Model KFC 241 H 7 ...

Page 8: ...ance IEEE 802 3u 100BASE FX Connector SC ST or Single SC model dependent Data Speed 100Mbps Duplex Mode Full duplex and optional half duplex Cable Types Multimode MMF 50 125 62 5 125μm Single mode SMF 9 125μm Supported Link Distance MMF up to 2km SMF single SMF model dependent Eye Safety compliance IEC825 Class 1 DC Power Input KFC 241 L Interfaces Screw type Terminal Block 3P TB 3P DC Jack D 6 3m...

Page 9: ... C Storage Temperature 30o C 85o C Relative Humidity 5 90 Basic Information Forwarding Throughput Full wire speed at 100M full duplex 10Mbps 14 880pps at 64 byte packets 100Mbps 148 800pps at 64 byte packets Packet Types Transparent and no modification for IEEE 802 3 standard packets IEEE 802 1Q VLAN tagged packets Packet Length Up to 1600 bytes under 100Mbps 10Mbps conversion No limit under 100Mb...

Page 10: ...V IEC 61000 4 3 RS Test Power Data Ports Level 1 2 3 IEC 61000 4 4 EFT Burst Test DC IN 1KV Data Ports 0 5KV IEC 61000 4 5 Surge Test DC IN 0 5KV Data Ports 1KV IEC 61000 4 6 CS Test DC IN Level 3 IEC 61000 4 8 PFMF Test Continuous 100A m XY 30 sec IEC 61000 4 11 Voltage Int Dips Interruption 100 250 periods Dips 30 25 periods Dips 60 0 5 period ...

Page 11: ...e connected device automatically Auto negotiation Function The copper port is featured with auto negotiation function and full capability in speed and duplex It performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established Far End Fault Function The FX port is facilitated with this function that conforms to ...

Page 12: ...spectively Smart Forward Function With this function the media converter can change to direct conversion automatically when it detects same speed on both copper port and fiber port Direct conversion method converts the signal between the copper port and the fiber port without storing the received packet on one port then forwarding to another port The media converter operates with the minimum laten...

Page 13: ...r from the rating of the media converters 2 2 Safety Cautions To reduce the risk of bodily injury electrical shock fire and damage to the product observe the following precautions z Do not service any product except as explained in your system documentation z Opening or removing covers may expose you to electrical shock z Only a trained service technician should service components inside these com...

Page 14: ...ackage a DIN rail bracket is provided and may have been pre installed on the device unit for mounting the converter in an industrial DIN rail enclosure The steps to mount the converter onto a DIN rail are 1 Install the mounting bracket onto the device unit as shown below Model KFC 241 L Model KFC 241 H 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until t...

Page 15: ...3 Clamp the unit to the DIN rail and make sure it is mounted securely Model KFC 241 L Model KFC 241 H 4 Make sure that there is proper heat dissipation from and adequate ventilation around the device 15 ...

Page 16: ...The final mechanical dimensions after installing DIN Rail mounting bracket are Model KFC 241 L with DIN Rail mounting bracket 16 ...

Page 17: ...Model KFC 241 H with DIN Rail mounting bracket 17 ...

Page 18: ...verter on a plane surface such as a wall a wood board or a metal plate in an industrial enclosure Screw the bracket and install it on the converters Model KFC 241 H Model KFC 241 L Make sure that there are proper heat dissipation from and adequate ventilation around the device Do not place heavy objects on the device 18 ...

Page 19: ...The final mechanical dimensions after installing panel mounting bracket are Model KFC 241 L with panel mounting bracket 19 ...

Page 20: ...Model KFC 241 H with panel mounting bracket 20 ...

Page 21: ...put from external power supply KFC 241 L KFC 241 H DC IN Terminal Block TB 3P Connector Screw type Terminal Block 3P Contacts DC IN Positive terminal DC IN Negative terminal PE Protective Earth Case terminal Power wires 24 12AWG IEC 0 5 2 5mm2 DC Jack Connector Jack D 6 3mm D 2 0mm Interface to typical AC DC power adapter plug 21 ...

Page 22: ...egotiation incapable 100BASE TX devices Network Cables 10BASE T 2 pair UTP Cat 3 4 5 EIA TIA 568B 100 ohm STP 100BASE TX 2 pair UTP Cat 5 EIA TIA 568B 100 ohm STP Link distance Up to 100 meters Note The TP port is featured with auto MDI MDI X crossover detection and configuration function No matter a straight through cable or crossover cable is connected the copper port can sense the receiving pai...

Page 23: ...lex SC 1310nm MMF 2km 20 14 31 max 0 min SL2 Duplex SC 1310nm SMF 20km 15 8 30 max 7 min SL3 Duplex SC 1310nm SMF 30km 15 8 34 max 0 min SL6 Duplex SC 1310nm SMF 60km 5 0 35 max 0 min W3515 BiDi SC Tx 1310nm SMF 15 20km 14 8 31 max 0 min Rx 1550nm W5315 BiDi SC Tx 1550nm SMF 15 20km 14 8 31 max 0 min Rx 1310nm Fiber Distance A reference connection distance Ext Extension of the model name Con FX Co...

Page 24: ...y State Interpretation PWR Power status ON Power on OFF Power off 100M TP port speed status ON Copper port operates in 100Mbps OFF 10Mbps LINK Port link status ON Link up and no traffic OFF Link fault Blink Rx Tx activities OL FX port optical link ON Optical signal is detected OFF No optical signal is detected 24 ...

Page 25: ...OFF Auto negotiation factory default JP1 TP auto mode ON Forced mode OFF Full duplex factory default JP2 TP duplex ON Half duplex OFF 100Mbps factory default JP3 TP speed ON 10Mbps OFF Enabled factory default JP4 Link Fault Pass Through ON Disabled OFF Smart mode factory default JP5 Forward mode ON Store and forward always OFF Enable factory default JP6 802 3x ON Disable Note Only the factory auth...

Reviews: