04/SHOCK ABSORBER, SWINGARM
29
200269-10
–
As soon as the pressure gauge has reached the specified value, set control lever
Damper
to
Vacuum
.
Specification
3
bar
The pressure gauge drops to the specified value.
0
bar
200270-10
–
As soon as the pressure gauge has reached the specified value, set control lever
Oil
reservoir
to
Vacuum
.
Specification
0
bar
The low pressure gauge
drops to the specified value.
8
mbar
200267-10
–
As soon as the low pressure gauge has reached the specified value, set control lever
Oil
reservoir
to
Equalize
Pressure
.
Specification
8
mbar
The pressure gauge drops to the specified value.
0
bar
200268-10
–
As soon as the pressure gauge has reached the specified value, set control lever
Damper
to
Pressure
.
Specification
0
bar
Oil is pumped into the shock absorber.
The pressure gauge rises to the specified value.
3
bar
200269-10
–
As soon as the pressure gauge has reached the specified value, set control lever
Damper
to
Vacuum
.
Specification
3
bar
The pressure gauge drops to the specified value.
0
bar
–
As soon as the pressure gauge has reached the specified value, press the
On/Off
switch.
Specification
0
bar
The vacuum pump is switched off.