40/ELECTRIC STARTER
189
26.1
Checking the starter motor
Condition
The starter motor has been removed.
700087-01
–
Connect the negative cable of a 12 volt power supply to the housing of the starter
motor. Connect the positive cable of the power supply briefly to connector
1
of the
starter motor.
» If the starter motor does not turn when the circuit is closed:
–
Change the starter motor.