RADEX
®
-N
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
47110 EN
30 of 31
24
Please observe protection
note ISO 16016.
Drawn:
2019-07-23 Pz/Wb
Replacing:
KTR-N dated 2018-07-17
Verified:
2019-07-26 Pz
Replaced by:
The ATEX marking of the RADEX
®
-N coupling is applied on the outer sheath or on the front side.
The lamina sets are not marked.
For the complete marking refer to the operating/assembly instructions and/or the delivery note/package.
Marking is as follows:
RADEX
®
-N
<Year>
I M2 Ex h I
Mb
-
40 °C ≤ T
a
≤ +130 °C
II 2G Ex h IIC T6
… T2
Gb
II 2D Ex h IIIC T80 °C
… T250 °C Db
-
30 °C ≤ T
a
≤ +60 °C … +230 °C
KTR Systems GmbH, Carl-Zeiss-Straße 25, D-48432 Rheine
Short marking:
(A short marking is only made if not possible differently for reason of space or functioning.)
RADEX
®
-N
<Year>
Deviating marking applies until 31st October 2019:
Short marking:
II 2GD c IIC T X/I M2 c X
Complete marking:
II 2G c IIC T6, T5, T4, T3 resp. T2 -30 °C
T
a
+75 °C, +90 °C,
+125 °C, +190 °C resp. +280 °C
II 2D c T 110 °C -30 °C
T
a
+100 °C/I M2 c -30 °C
T
a
+140 °C
Substance group - gases, fogs and vapours:
The marking with explosion group llC includes the explosion groups llA and llB.
Substance group - dusts:
The marking with explosion group lIlC includes the explosion groups lIlA and lIlB.
If the symbol
was punched in addition to marking
, the coupling component was supplied by KTR as an
unbored or pilot bored version (see chapter 4.2 of the present operating/assembly instructions).
10
Enclosure A
Advice and instructions regarding the use in
potentially explosive atmospheres
10.3
marking of coupling for potentially explosive atmospheres