KTR Kupplungstechnik
GmbH
D-48407 Rheine
B o W e x - E L A S T I C
®
Operating-/Assembly Instructions
Design 065 (HEW1 and HEW2)
KTR-N
sheet:
edition:
40114 E
8
4
Gezeichnet:
08.04.04 Sha/Hk
Ersatz für:
KTR-N vom 01.12.99
Schutzvermerk
ISO 16016 beachten.
Geprüft:
08.04.04 Sha
Ersetzt durch:
5 Enclosure A
Hints and instructions regarding the use in
hazardous areas
design 065:
hub / elastomer part / coupling flange
5.1 Control intervals for couplings in
hazardous areas
explosion group
control intervals
II 2G c IIB T4
A checking of the circumferential backlash and a visual check of the eleastomer part must
be effected after 3000 operating hours for the first time, after 6 months at the latest.
If you note an unconsiderable or no wear at the elastomer part after this first inspection, the
further inspections can be effected, in case of the same operating parameters, respectively
after 6000 operating hours or after 18 months at the latest.
If you note a considerable wear during the first inspection, so that a change of the
elastomer part would be recommended, please find out the cause according to the table
„Breakdowns“, as far as possible.
The maintenance intervals must be adjusted according to the changed operating
parameters.
BoWex
®
-coupling
picture 8: BoWex-ELASTIC
®
(design HEW1)
Here the backlash between the hub and the nylon toothing by the elastomer part must be checked by a torsional
backlash.
The friction / wear may only be X
max.
of the original toothing strength before the nylon elastomer part must be
exchanged.
When reaching the torsional backlash
∆
S
max
, the nylon elastomer part must be exchanged immediately,
irrespective of the inspection intervals.