KTS-Electronic GmbH & Co. KG
– PULSE AR III
4
3. Electronic unit
The electronic unit is stored in a hard-wearing box. Besides the display 4 control
elements are located on the front.
The menu knob can be switched to four positions:
ID:
In this search mode the discriminator comes into operation. Thereby an optical and
acoustical discrimination takes place. The various metals are signaled through
differing tones and conductivity values.
AM (all metal mode)
:
All metals are indicated acoustically and optically through the value number (without
discrimination). The metals are not tested for their conductivity.
This position has the advantage, that you can detect with highest sensibility and
through the value number one can evaluate the object
’s depth position. The lower the
value number, the deeper the metal object is hidden. The
object’s shape can also be
identified.
BAT
:
Scale to control the battery condition. If display shows a value of approx. 100 the
device is fully charged.
OFF
: Inoperative
RESET:
Automatic zero balance. By pressing the RESET-button the device is aligned to the
respective ground surface.
FREQ.:
Frequency setting controller
– the smaller the item you are searching for, the
smoother the adjustment must be.
VOLUME:
Volume control.