background image

KTS-Electronic GmbH & Co. KG 

– PULSE AR III 

3.  Electronic unit 

 
The electronic unit is stored in a hard-wearing box. Besides the display 4 control 
elements are located on the front. 
 

 

 
The menu knob can be switched to four positions: 
 

ID: 

In  this  search mode the  discriminator  comes  into  operation.  Thereby  an  optical and 
acoustical  discrimination  takes  place.  The  various  metals  are  signaled  through 
differing tones and conductivity values. 
 

AM (all metal mode)

All metals are indicated acoustically and optically through the value number (without 
discrimination). The metals are not tested for their conductivity. 
 
This  position  has  the  advantage,  that  you  can  detect  with  highest  sensibility  and 
through the value number one can evaluate the object

’s depth position. The lower the 

value number, the deeper the metal object is hidden. The 

object’s shape can also be 

identified. 
 

BAT

Scale  to  control  the  battery  condition.  If  display  shows  a  value  of  approx.  100  the 
device is fully charged. 
 

OFF

: Inoperative 

 
RESET:

 

Automatic zero balance.  By pressing the RESET-button the device  is aligned to the 
respective ground surface. 
 

FREQ.:

 

Frequency  setting  controller 

–  the  smaller  the  item  you  are  searching  for,  the 

smoother the adjustment must be. 
 

VOLUME: 

Volume control. 
 

 

Summary of Contents for PULSE AR III

Page 1: ...PULSE AR III Pulse Induction based Metal Detector User s Manual KTS Electronic GmbH Co KG Germany...

Page 2: ...ectronic unit 4 4 Search process 6 5 ID Metal Discrimination 7 6 Installation 8 7 Appropriate handling 8 8 Adjustment 9 9 Indication of metal 9 10 Usage of appropriate searchcoils 9 11 Rechargeable ba...

Page 3: ...sal if any questions should arise Your KTS Electronic Team 2 Scope of delivery PULSE AR III Combi depending on scope of delivery in set included Electronic unit with integrated rechargeable high perfo...

Page 4: ...e number without discrimination The metals are not tested for their conductivity This position has the advantage that you can detect with highest sensibility and through the value number one can evalu...

Page 5: ...The connector for the coil is left hand sided The plug of the searchcoil has to be plugged into the socket Before removing the plug the jack must be pressed only then it is possible to pull out the pl...

Page 6: ...d value leads to a better analysis of the discovered object Search recommendations and hints for Reset operation During the search process be sure that you do not carry items of metal with you This co...

Page 7: ...ject Before excavation however further details should be taken into account and your own search experience should be used for help The more intense the sound the larger the object and the nearer its p...

Page 8: ...carbon tube into the armrest 2 Connect the telescope bar with the searchcoil and wrap the cable of the coil around the bar 3 The electronic unit is placed in a bag insert the plug of the searchcoil t...

Page 9: ...ly helps to locate the exact spot of discovery but it also detects based on the duration of the sound the object s shape Examples A long lasting high tone in longitudinal direction stands for a slim i...

Page 10: ...iate for the search in wells narrow excavations and underwater At the same time it can be helpful to find micro objects 1 x 1 m search frame Preferably used for the deep sounding after medium sized an...

Page 11: ...ame are firmly connected to each other Note Turn off the metal detector in case you want to change the searchcoil then connect the selected searchcoil Please press the Reset button after you have star...

Page 12: ...as placed on stability and interference immunity so that the search is disturbed as little as possible Despite the multitude of filters and modulators it is to our regret possible that certain soil co...

Page 13: ...mbH Co KG assumes no responsibility for possible legal violations In case of doubts we recommend a comprehensive consultation with an attorney or national monument offices 15 Warranty According to the...

Page 14: ...fit setbacks or operating failures After expiry of warranty KTS GmbH Co KG can agree upon a service after expiry of guarantee In this case repairing and shipment will be charged 16 Contact KTS Electro...

Reviews: