Maintenance
RG268-8135-6
167
01/2019
Every 2 years
Coolant - change
Open the engine compartment and side cover (page 144).
Place a container with a minimum capacity of 5 litres under the coolant drain plug.
Remove the radiator cap (1) by turning it anticlockwise.
Open the central coolant drain plug (1) and drain the coolant
completely.
Flush out the cooling system if the coolant is very dirty. To do this,
spray water without additives into the cooling system with a hose
through the filler opening until clear water emerges from the outlet.
Close the central drain.
To perform the following tasks, the dozer and boom must be positioned in the forward direction of
travel.
Drain only when engine is cold, otherwise there is a risk of scalding!
Filling capacity
Canopy
Cab
Radiator
2.4 litres
2.6 litres
Expansion reservoir
0.6 litres
0.6 litres
STOP
1