12
Section 2: Equipment Hook-up & Unhook
AP-SBL2566, AP-SBL2574, & AP-SBL2584 Snow Blowers 370-478MK
10/07/16
Hydraulic Hose Hook-up
!
DANGER
To prevent serious injury or death:
Refer to Figure 2-4 on page 13:
Two high pressure hydraulic outlets are required for the
hydraulic motor and one outlet for the case drain.
1.
Route hydraulic hoses along the most convenient
path to access your skid steer or tractor mounted
hydraulic reservoir couplings.
o
Kubota Hose Stay
Figure 2-2
IMPORTANT:
Collect and dispose all oil spills and
leaks in an environmentally safe manner.
IMPORTANT:
Hose routing is the responsibility of
the owner/operator. Pinched and/or stretched hoses
are not covered under the warranty.
IMPORTANT:
Make sure coupler fittings on the
hydraulic hoses and power machine are clean
before connecting them together.
NOTE:
If attaching to a Kubota skid steer, route
hydraulic hoses through Kubota’s SVL or SSV Hose
Stay as shown in Figure 2-2. Purchase
SVL Hose
Stay #S6689 or SSV Hose Stay #77700-07225
through your nearest Kubota dealer. Refer to your
skid steer Operator’s Manual for more instructions.
37394
Hose Stay Kit
2.
Clean quick connect couplers of dirt and then
connect couplers (#1 & #2) to the skid steer couplers
or couplers at the tractor mounted hydraulic
reservoir. Make sure quick connect couplers have
fully engaged. If they have not, check the following:
a. Make sure couplers are same size and type.
b. Make sure hydraulic pressure has been released.
3.
If case drain line is fitted with the optional coupler,
then connect that coupler (#3) to the tank/sump
coupler and skip to step 5 below.
4.
If screwing case drain line directly to the tank/sump:
a. Remove plastic cap and wrap teflon tape around
pipe threads on end of case drain line (#3).
b. Screw case drain line (#3) to your equipment’s
tank/sump port until tight. All required adapter
fittings are supplied by customer.
5.
Turn auxiliary hydraulics on to check impeller
rotation. The impeller should rotate counterclockwise
viewed from the operator’s seat and clockwise
viewed facing impeller and auger from the front. If
impeller rotates incorrectly, switch male and female
couplers on the hydraulic hoses and reconnect
hoses.
6.
Cable ties to be added at end of solenoid hook-up.
Solenoid Hook-up
There are two optional wiring harnesses and all connect
the same way to the Snow Blower solenoids (#1 & #2) but
connect differently to the skid steer or tractor. See
“Electrical Control Harness (Optional)”
a detailed descriptions.
1.
Skip to step 2 if optional wire harness (#4) has a 6 pin
connector. Otherwise, continue with step 2 below.
2.
If solenoid harness has a 14 pin connector, attach
harness to the 14 pin connector located on the end of
the loader arm. Skip to step 4 on this page.
3.
Install
“Control Harness With Deutsch 2 Pin Plug”