18
Section 3: Options
AP-SBL2566, AP-SBL2574, & AP-SBL2584 Snow Blowers 370-478MK
10/07/16
Assembly Instructions
A detailed listing of parts for this accessory kit is provided
on page 17. Use this list to identify components during
assembly and as a checklist to inventory parts received.
Please contact your local Kubota dealer for missing parts.
Initial Preparations
The steps listed below must be followed before installing
this kit:
1.
Park on a flat surface, lower lift arms and put
attachment flat on the ground. Turn off engine and
engage park brake.
2.
If included, raise seat bar and move controls until both
lock.
3.
Remove key to prevent unauthorized starting.
4.
Use steps, grab-handles and skid-resistant surfaces
when getting on or off the loader.
Mount Control Box (#2) in Cab
Refer to Figure 3-8 & Figure 3-5 on page 17:
1.
Locate control box (#2) inside the cab in an area
where the box is easy to access and operate.
2.
Fasten control box (#2) to that location with hardware
furnished by the customer.
3.
Plug 11'-0” long wire harness (#3) and 5'-0” long
power cord (#1) to control box (#2).
Connect to Power
Refer to Figure 3-5 on page 17 & Figure 3-9:
4.
Plug opposite end of power cord (#1) to Kubota’s
2-pin Deutsch plug “A” located behind driver’s seat.
5.
Make sure power cord (#1) is placed in an
out-of-the-way area to prevent operator entanglement
with the cord.
6.
Add zip ties (#5) to power cord (#1) as needed.
Refer to Figure 3-10:
7.
Fuse “B” is supplied by customer. Install 10 amp
fuse “B” in Kubota’s fuse box slot #17 labeled
“Electrical Outlet-2”.
Route Wire Harness (#3)
Refer to Figure 3-5 on page 17
and Figure 3-11 on page 19:
!
DANGER
To prevent serious injury or death:
Make sure wire harness does not
become entangled, stretched, or kinked while loader
arms are being raised and lowered.
Mount Control Box
Figure 3-8
Kubota Power Connection (Located Behind Drive Seat)
Figure 3-9
Installation of 10 amp Fuse
Figure 3-10
1.
Route wire harness (#3) from control box (#2) to the
loader arm with quick release couplings in such a
way that the front cab door can be shut and latched.
2.
Attach end of wire harness (#3) near the quick
release hydraulic couplings on the loader arm with
zip tie (#5).
3.
Make sure wire harness (#3) is placed in an
out-of-the-way area inside the cab to prevent
operator entanglement with harness.
4.
Also, make sure harness does not become
entangled, stretched, or kinked while loader arms are
being raised and lowered.
5.
Secure wire harness (#3) as needed with
zip ties (#5).
2
35239
1
3
37389
1
A
37390
B