GENERATOR
GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
2-S18
(2) Emergency Relay Activation
Emergency Relay Circuit
1. When the engine is running at rated rpm's connect the lead
wires to the terminal of the oil pressure switch (1) or the water
temperature sensor (2).
2. Also ground the other end of the lead wires to an unpainted
portion of the engine frame.
(In normal operation)
• The stop solenoid activate and the engine stops automatically.
• After 7 to 13 seconds ia "tick" sound can be heard and the stop
solenoid is released.
9Y1211607GRS0021US0
Oil Pressure Switch
1. The oil pressure switch (1) has continuity when the engine is
stopped and has no continuity while the engine is running.
2. Replace the oil pressure switch (1) if it is defective.
9Y1211607GRS0022US0
Water Temperature Sensor
1. Insert the water temperature sensor (1) in the engine oil, and
continue the circuit when the oil temperature rises to 112 to
118 °C (234 to 244 °F).
2. Check that the resistance is 0 ohm in case water temperature
sensor is defective.
IMPORTANT
• Be careful when handling the water temperature sensor so
that you do not drop it.
• When assembling the sensor, apply sealing agent to the
threads, and then screw it in firmly.
• Make a test run after installation, to check for any water
leaks.
9Y1211607GRS0023US0
(1) Oil Pressure Switch
(2) Water Temperature Sensor
Resistance (Switch
terminal -Chassis)
In normal state
Infinity
At pressure over
approx. 98 kPa
(1.0 kgf/cm
2
, 14 psi)
0
Ω
(1) Oil Pressure Switch
Water temperature
sensor
Factory specification
Water temperature above
than 112 to 118 °C (234 to
244 °F). Contact
ON
.
(1) Water Temperature Sensor
KiSC issued 06, 2016 A