GENERATOR
GL6000A-AU-B, GL6000D-AU-B,GL9000A-AU-B, GL9000D-AU-B, WSM
2-S23
[3] SERVICING
(1) Terminal Voltage for Each Part During Normal Periods (No-load Periods)
Output Terminal
1. With the MCB (1) and RCBO (2) in the
ON
position, measure the
voltage in each phase and each line.
2. If the factory specification is not indicated, inspect the output
circuit or the wiring harness.
(Refer to 2-M16.)
9Y1211607GRS0030US0
(2) Stator Coil
Main Coil Winding
1. Test for continuity between coil leads with a milliohm meter.
Many kind of wiring have been arranged in the stator depending
on the voltage variation.
2. If the resistance is not as specified, replace the stator or contact
service station.
(Refer to 2-M16.)
* Measurement is not possible with a regular tester.
9Y1211607GRS0031US0
Detecting Coil
1. Measure the coil resistance between each auxiliary winding.
2. If the factory specification is not indicated, replace the stator or
contact service station.
(Refer to 2-M16.)
9Y1211607GRS0032US0
Output voltage
Factory specification
Rated voltage 7 or 8 %
(1) MCB (Miniature Circuit Breaker)
(2) RCBO
(Residual Current Circuit Breaker)
Resistance
Factory specification
[A] GL6000A-AU-B, GL6000D-AU-B
[B] GL9000A-AU-B, GL9000D-AU-B
Resistance
Factory specification
[A] GL6000A-AU-B, GL6000D-AU-B
[B] GL9000A-AU-B, GL9000D-AU-B
KiSC issued 06, 2016 A