61
PERIODIC SERVICE
ENGLISH
A higher boiling point is obtained by using a radiator
pressure cap which permits the development of pressure
within the cooling system.
5. Adding the LLC
(1) Add only water if the coolant level reduces in the
cooling system by evaporation.
(2) If there is a mixture leak, add the LLC of the same
manufacturer and type in the mixing ratio 50%.
6. When the LLC is mixed, do not employ any radiator
cleaning agent. The LLC contains anti-corrosive
agent. If mixed with the cleaning agent, sludge may
build up, adversely affecting the engine parts.
7. Kubota's genuine long-life coolant has a service life of
2 years. Be sure to change the coolant every 2000
hours or every 2 years whichever comes faster.
A
The above data represent industry standards that
necessitate a minimum glycol content in the
concentrated anti-freeze.
EVERY 4 YEARS
B
Replacing Fuel Lines
Consult your local KUBOTA Dealer for this service.
B
Replacing Engine Breather Hose
Consult your local KUBOTA Dealer for this service.
B
Replacing Radiator Hose
Replace hoses and clamp bands every 4 years or earlier
if you checked and found that hoses are swollen,
hardened or cracked.
B
Replacing Mower Gear Box Oil Seal
Consult your local KUBOTA Dealer for this service.
B
Replacing Intake Air Line
(See "Checking Intake Air Line" in "EVERY 1 YEAR" in
"PERIODIC SERVICE" section.)
SERVICE AS REQUIRED
B
Replacing Fuses
1. Open the hood.
2. Remove the blown fuse.
3. Place a new 3A, 10A, 15A fuse or 40A slow blow fuse
in position.
* Never add any long-life coolant of different
manufacturer. (Different brands may have
different additive components, and the engine
may fail to perform as specified.)
(1) Fuse location