65
PERIODIC SERVICE
ENGLISH
Tighten each bolt and nut with following torque.
A
Bolt M12
77.6 to 90.2 N-m (8.0 to 9.2 kgf-m)
A
Bolt M10 and Nut M10
48.1 to 55.9 N-m (4.9 to 5.7 kgf-m)
5. To install a new belt, reverse the above procedure.
B
Bleeding Fuel System
Air must be removed:
1. When the fuel filter or lines are removed.
2. When tank is completely empty.
3. After the machine has not been used for a long period
of time.
C
Bleeding procedure is as follows:
1. Fill the fuel tank with fuel.
2. Turn the key switch to the "ON" position and hold it for
about 10 seconds.
3. Start the engine and run for about 30 seconds, and
then stop the engine.