61
PERIODIC SERVICE
ENGLISH
A
Since the fine filings in the oil can damage the
precision component parts of the hydraulic system, the
end of the suction line is provided with an oil strainer.
B
Replacing Transmission Oil Filter
Cartridge
To avoid personal injury:
A
Be sure to stop the engine and remove the key
before changing the oil filter cartridge.
A
Allow transmission case to cool down
sufficiently; oil can be hot and may cause
burns.
1. The oil filter cartridge must be changed every 200
service hours.
2. Remove the grass container and clean the area
indicated. (See "GRASS CATCHER MOUNTING"
section.)
3. Loosen the wing bolt and remove the filter cover. Then
remove the oil filter cartridge by using the filter wrench.
4. Lightly tighten the screw (A) by using a screwdriver.
5. Apply a slight coat of oil onto the cartridge gasket.
6. Tighten the filter quickly until it contacts the mounting
surface. Tighten filter by hand an additional 1/2 turn
only.
7. Assemble the cover and mount the grass container.
8. After the new cartridge has been replaced, the
transmission fluid level normally lowers a little. Add
fluid to proper level. Check for oil leaks around filter
gasket.
A
To prevent serious damage or premature failure to the
hydraulic system, the replacement filter must be a
highly efficient, 10
filter. Use only a genuine
KUBOTA filter or its equivalent.
(1) Wing bolt
(2) Filter cover
(3) Transmission oil filter cartridge
Summary of Contents for GR1600-II
Page 2: ...ENGLISH MODELS GR1600 II GR2100 II OPERATOR S MANUAL RIDING MOWER 1BDAHAGAP0360 ...
Page 5: ...FRANÇAIS MODELES GR1600 II GR2100 II TONDEUSE AUTOPORTEE 1BDAHAGAP0360 ...
Page 8: ...DEUTSCH MODELLE GR1600 II GR2100 II AUFSITZMAHER 1BDAHAGAP0360 ...
Page 12: ......
Page 13: ......
Page 24: ...7 SAFE OPERATION ENGLISH 8 DANGER WARNING AND CAUTION LABELS ...
Page 25: ...SAFE OPERATION 8 ENGLISH ...
Page 26: ...9 SAFE OPERATION ENGLISH ...