PERIODIC SERVICE
62
ENGLISH
B
Checking Radiator Hose and Clamp
Check to see if radiator hoses are properly fixed every 200
hours of operation or six months, whichever comes first.
1. If hose clamps are loose or water leaks, tighten clamps
securely.
2. Replace hoses and tighten hose clamps securely, if
radiator hoses are swollen, hardened or cracked.
B
Changing Front Axle Case Oil
[GR2100-II]
1. Park the machine on a firm, flat and level surface.
2. To drain the used oil, remove the right and left drain
plugs and filling plug at the front axle case and drain
the oil completely into the oil pan.
3. After draining reinstall the drain plugs.
4. Remove the right and left breather plugs.
5. Fill with the new oil up to the upper notch on the
dipstick.
(See "LUBRICANTS" in "MAINTENANCE" section.)
A
After ten minutes, check the oil level again; add oil to
prescribed level.
6. After filling reinstall the filling plug and breather plugs.
(1) Radiator core
(2) Radiator hose
Oil capacity
1.9 L (2.0 U.S.qts)
(1) Breather plug
(2) Filling plug with dipstick
(3) Drain plug
(A) Oil level is acceptable
within this range