S-15
J SERIES, WSM
GENERAL
(2) Engine
W11416550
Symptom
Probable Cause
Solution
Reference
Page
Engine Does Not
Start.
(Starter Does Not
Run.)
• No fuel
• Air in the fuel system
• Water in the fuel system
• Fuel pipe clogged
• Fuel filter clogged
• Excessively high viscosity of fuel or engine oil
at low temperature
• Fuel with low cetane number
• Fuel leak due to loose injection pipe retaining
nut
• Incorrect injection timing
• Fuel camshaft worn
• Injection nozzle clogged
• Injection pump malfunctioning
• Seizure of crankshaft, camshaft, piston,
cylinder or bearing
• Compression leak from cylinder
• Improper valve timing
• Piston ring and cylinder worn
• Excessive valve clearance
• Battery discharged
• Starter malfunctioning
• Key switch malfunctioning
• Wiring disconnected
Replenish fuel
Vent air
Change fuel and
repair or replace fuel
system
Clean
Clean or change
Use specified fuel or
engine oil
Use specified fuel
Tighten retaining nut
Adjust
Replace
Clean
Repair or replace
Repair or replace
Replace head
gasket, tighten
cylinder head screw,
glow plug and nozzle
holder
Correct or replace
timing gear
Replace
Adjust
Charge
Repair or replace
Repair or replace
Connect
–
–
–
–
–
S-40
S-3
S-3
S-61
S-105
–
S-106
–
–
S-58, 61
–
S-89, 99
S-60
S-108
–
–
Engine Revolution Is
Not Smooth.
• Fuel filter clogged or dirty
• Air cleaner clogged
• Fuel leak due to loose injection pipe retaining
nut
• Injection pump malfunctioning
• Incorrect nozzle opening pressure
• Injection nozzle stuck or clogged
• Governor malfunctioning
Clean or change
Clean or change
Tighten retaining nut
Repair or replace
Adjust
Repair or replace
Repair or replace
S-40
S-40
S-61
–
S-106
S-106
–
KiSC issued 10, 2016 A
Summary of Contents for J106-AUS
Page 1: ...WORKSHOP MANUAL DIESEL GENERATOR J SERIES KiSC issued 10 2016 A ...
Page 20: ...M 7 GENERATOR J SERIES WSM 3 Flow Chart KiSC issued 10 2016 A ...
Page 21: ...M 8 J SERIES WSM GENERATOR W1012333 KiSC issued 10 2016 A ...
Page 23: ...M 10 J SERIES WSM GENERATOR 5 WIRING DIAGRAM KiSC issued 10 2016 A ...
Page 24: ...M 11 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 25: ...M 12 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 26: ...M 13 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 27: ...M 14 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 28: ...M 15 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 29: ...M 16 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 30: ...M 17 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 31: ...M 18 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 32: ...M 19 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 33: ...M 20 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 34: ...M 21 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 35: ...M 22 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 36: ...M 23 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 37: ...M 24 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 38: ...M 25 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 39: ...M 26 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 40: ...M 27 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 41: ...M 28 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 42: ...M 29 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 43: ...M 30 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 44: ...M 31 GENERATOR J SERIES WSM KiSC issued 10 2016 A ...
Page 45: ...M 32 J SERIES WSM GENERATOR KiSC issued 10 2016 A ...
Page 54: ...S 8 J SERIES WSM GENERAL D Engine Circuit Troubleshooting Z482 D722 KiSC issued 10 2016 A ...
Page 55: ...S 9 J SERIES WSM GENERAL KiSC issued 10 2016 A ...
Page 56: ...S 10 J SERIES WSM GENERAL KiSC issued 10 2016 A ...
Page 57: ...S 11 J SERIES WSM GENERAL KiSC issued 10 2016 A ...
Page 58: ...S 12 J SERIES WSM GENERAL KiSC issued 10 2016 A ...
Page 59: ...S 13 J SERIES WSM GENERAL E Engine Circuit Troubleshooting D1005 V1305 KiSC issued 10 2016 A ...
Page 60: ...S 14 J SERIES WSM GENERAL KiSC issued 10 2016 A ...