Taking out of service and storage
103
TAKING OUT OF SERVICE AND STORAGE
If the excavator is taken out of service for up to six months, the measures before, during and after taking out of
service must be carried out as described below. If the vehicle is to be taken out of service for a period of over
six months, contact the manufacturer for additional measures.
Safety rules for taking out of service and storage
The general safety rules (page 12), the safety rules for operation (page 45) and the safety rules for mainte-
nance (page 79) apply.
When taking the excavator out of service, secure it against unauthorised use.
Storage conditions
The storage place must have a sufficient bearing capacity for the weight of the excavator.
The storage place must be frost-free, dry and well ventilated.
Measures before taking out of service
Clean and dry the excavator thoroughly (page 84).
Check the hydraulic oil level, add oil if necessary (page 49).
Change the engine oil and oil filter (page 86).
Drive the excavator to the storage place.
Remove the battery (page 93) and store it in a dry and frost-free room. If necessary, connect it to a trickle
charger.
Grease the front attachments (page 50).
Grease the pitch bearing (page 95).
Grease the swivel gear (page 94).
Check the antifreeze strength of the coolant, add coolant if necessary (page 84).
Grease the hydraulic cylinder piston rods.
Measures during taking out of service
Charge the battery regularly (page 93).