119
LIST OF SCREENS
LOCKING AND RELEASING THE DIESEL PARTICULATE FILTER (DPF) REGENERATION
Press the inhibit switch (1).
The automatic DPF regeneration is locked and the indicator (2) in the switch lights up.
The following is meaning and required operator action.
(1) Inhibit switch
(2) Inhibit switch indicator
Inhibit
switch
Warning
lamp
Display
Meaning
Required operator action
Lights up
(yellow)
No
lighting
---
A
Auto regeneration process is
locked.
A
The state is before requirement of
regeneration.
A
When inhibit switch turns into
blinking, it requires regeneration.
---
Blinking
(yellow)
Blinking
(yellow)
A
Auto regeneration process is
locked.
A
Operator needs preparation of
DPF regeneration.
A
Move the machine to a safe place
and release the inhibit switch.
A
Increase the engine speed over
1650 rpm. Auto regeneration
starts.
A
Make sure that no people,
animals, plants and flammable
materials are within the immediate
working area.
(Refer to No. 39 in "NAVIGATION
LIST OF SCREENS" section.)