II - 34
WSM Minor Change
II Service Engineering Section
f. S/P valve start point setting
1. Performance characteristics profile: Knob shift amount vs Output current
1) A dead zone is provided to keep the thumb intact in neutral. Some margins are also given to
start the thumb at each end.
2) The right-end, neutral, and left-end settings of the knob are presupposed to be in memory.
3) The profile is flexibly modifiable even for maximum engine rpm and idling speed. When the
engine runs at middle speed, for example, the average is determined from the idling map and
maximum map and finally outputted.
4) Suppose that the thumb starts moving at the current of 500 mA. The knob's operating map must
begin with 450 mA because it is necessary to provide an inching zone and give better feeling.
5) At the 500mA level, however, there could be fluctuations due to the control valve, proportional
control valve, hoses and other factors. The meter keeps the initial map and performs as well,
but the inching zone might be longer or shorter depending on the machine.
6) The starting point setting is made to cope with such problem. In the setting mode, the meter
shows the current gradually higher from 450 mA. When the thumb starts moving, the operator is
supposed to press and release the button twice for releasing and grasping of the thumb. The
meter memorizes the then setting.
The following correction is made for control.
Address 48:
o
Release R Deviation
Address 49:
o
Grasp L Deviation
Proportional control valve B
Proportional control valve A
Right end
Left end
Neutral
Knob
950 mA
450 mA
Current
Proportional control valve B
Proportional control valve A
Right end
Left end
Neutral
Knob
950 mA
450 + (The value in the address 49)
450 + (The value in the address 48)
Current
Summary of Contents for KX101-3a
Page 68: ...II 57 WSM Minor Change II Service Engineering Section...
Page 72: ...II 60 WSM Minor Change II Service Engineering Section 7 7 1 1 72548...
Page 74: ...II 62 WSM Minor Change II Service Engineering Section...
Page 75: ...II 63 WSM Minor Change II Service Engineering Section c Control valve 1 PP version KX161 3S...
Page 76: ...II 64 WSM Minor Change II Service Engineering Section 2 EU KTA version KX161 3D S...
Page 77: ...II 65 WSM Minor Change II Service Engineering Section 3 Third line version EU KTA KX161 3D S...
Page 83: ...II 71 WSM Minor Change II Service Engineering Section...
Page 86: ...II 74 WSM Minor Change II Service Engineering Section 2 Pilot control line EU version KX161 3D...
Page 87: ...II 75 WSM Minor Change II Service Engineering Section 3 Pilot delivery line KX161 3S...
Page 90: ...II 78 WSM Minor Change II Service Engineering Section 6 Delivery hose KX91 3S U35S U35 3S KTA...
Page 91: ...II 79 WSM Minor Change II Service Engineering Section...
Page 95: ...II 83 WSM Minor Change II Service Engineering Section 2 S P valve...
Page 96: ...II 84 WSM Minor Change II Service Engineering Section 3 Heat up circuit...
Page 104: ...II 92 WSM Minor Change II Service Engineering Section...
Page 105: ...II 93 WSM Minor Change II Service Engineering Section 1 KX91 3S KTC version...
Page 106: ...II 94 WSM Minor Change II Service Engineering Section 2 KX91 3S KCL KTA version...
Page 107: ...II 95 WSM Minor Change II Service Engineering Section 3 KX91 3D EU version...
Page 108: ...II 96 WSM Minor Change II Service Engineering Section 4 KX101 3D EU version...
Page 109: ...II 97 WSM Minor Change II Service Engineering Section 5 U35S KTC version...
Page 110: ...II 98 WSM Minor Change II Service Engineering Section 6 U35 3S KTA version U35S KCL version...
Page 111: ...II 99 WSM Minor Change II Service Engineering Section 7 U35 3D EU version...
Page 112: ...II 100 WSM Minor Change II Service Engineering Section 8 KX121 3S KTC KCL version...
Page 113: ...II 101 WSM Minor Change II Service Engineering Section 9 KX121 3S KTA version...
Page 114: ...II 102 WSM Minor Change II Service Engineering Section 10 KX121 3D EU version...
Page 115: ...II 103 WSM Minor Change II Service Engineering Section 11 KX161 3S KTC KCL KTA version...
Page 116: ...II 104 WSM Minor Change II Service Engineering Section 12 KX161 3D EU version...
Page 117: ...II 105 WSM Minor Change II Service Engineering Section 13 U45 3S KTA version...
Page 118: ...II 106 WSM Minor Change II Service Engineering Section 14 U45 3D EU version...
Page 124: ...II 112 WSM Minor Change II Service Engineering Section QFGN 8 5 6T 25 DG...
Page 125: ...II 113 WSM Minor Change II Service Engineering Section...
Page 131: ...II 119 WSM Minor Change II Service Engineering Section...
Page 132: ...II 120 WSM Minor Change II Service Engineering Section...
Page 173: ...II 161 WSM Minor Change II Service Engineering Section 3 Operational flow chart 3 1...
Page 174: ...II 162 WSM Minor Change II Service Engineering Section 3 2...
Page 192: ...II 180 WSM Minor Change II Service Engineering Section...
Page 196: ...II 184 WSM Minor Change II Service Engineering Section...
Page 201: ...II 189 WSM Minor Change II Service Engineering Section 2 KX91 3S U35S U35 3S PP version...
Page 202: ...II 190 WSM Minor Change II Service Engineering Section 3 KX91 3D 101 3D U35 3D EU version...
Page 204: ...II 192 WSM Minor Change II Service Engineering Section...
Page 205: ......