FRONT LOADER
LA525, LA765, WSM
1-M1
1. HYDRAULIC CIRCUIT
To operate the front loader, the hydraulic oil pressurized by the hydraulic pump flows from
P
port through the
boom control valve (5) and the bucket control valve (6) to
P.B.
port.
Specification of Hydraulic Parts
9Y1211014FLM0001US0
(1) Hydraulic Block
(2) Control Valve Assembly
(3) Boom Cylinder
(4) Bucket Cylinder
(5) Boom Control Valve
(6) Bucket Control Valve
(3 Position Type)
(7) Relief Valve
P:
P Port
T:
T Port
A1: A1 Port
B1: B1 Port
A2: A2 Port
B2: B2 Port
P.B.:Power Beyond Port
a:
From Pump
b:
To 3-Point Hydraulic
System
(7)
L2501: 15.2 to 16.2 MPa
(155 to 165 kgf/cm
2
, 2210 to 2340 psi)
L3301/L3901: 15.7 to 16.6 MPa
(160 to 170 kgf/cm
2
, 2280 to 2410 psi)
L4701: 17.1 to 18.1 MPa
(174 to 185 kgf/cm
2
, 2480 to 2630 psi)
KiSC issued 06, 2017 A