ASSEMBLY INSTRUCTIONS
12
4. Attach the 3rd function valve cover to the front loader
main frame RH.
A
Pay attention to the direction of the bolts.
(Apply them as shown in the figure.)
5. Install the 3rd function valve assembly on the 3rd
function valve cover.
6. Connect the hoses to the 3rd function assembly.
(1) 3rd function valve cover
(2) 2-M10 x 40 bolts with washers
(3) 2-M10 spring lock washers
(4) 2-M10 nuts
Tightening torque
48.1 to 55.8 N m
(4.9 to 5.7 kgf m)
(35.5 to 41.2 lbf ft)
(1) 3rd function valve cover
(2) 3rd function valve assembly
(3) 2-M10 x 25 bolts with washer
Tightening torque
43.3 to 50.3 N m
(4.41 to 5.13 kgf m)
(31.9 to 37.1 lbf ft)
(1) Inlet hose
(2) Outlet hose