131
PERIODIC SERVICE
B
Checking Intake Air Heater
[M100GX, M110GX]
Consult your local KUBOTA Dealer for this service.
B
Checking and Cleaning EGR System
Consult your local KUBOTA Dealer for this service.
B
Cleaning DPF Muffler
C
Removal of ash
The longer the DPF operates, the more ash (burnt
residue) is collected in the filter. Too much ash build-up
adversely affects the DPF performance. Consult your
local KUBOTA Dealer to clean the filter.
A
The DPF needs cleaning with a specific cleaning
device. Do not clean the DPF by disassembling, and
attempt by yourself, consult your local KUBOTA
Dealer.
EVERY 1 YEAR
B
Replacing Air Cleaner Primary Element
and Secondary Element
(See "Cleaning Air Cleaner Primary Element" in "EVERY
100 HOURS" in "PERIODIC SERVICE" section.)
B
Checking Air-Conditioner Pipe and Hose
1. Check to see that all lines and hose clamps are tight
and not damaged.
2. If hoses and clamps are found worn or damaged,
consult your local KUBOTA Dealer for this service.
B
Checking CAB Isolation Cushion
Check the cushion for any breakage or fatigue. Replace
them if they are deteriorated.
B
Checking Exhaust Manifold
Consult your local KUBOTA Dealer for this service.
B
Checking DPF Differential Pressure
Sensor Pipe
Consult your local KUBOTA Dealer for this service.
B
Checking EGR Pipe
Consult your local KUBOTA Dealer for this service.
EVERY 2 YEARS
B
Flushing Cooling System and Changing
Coolant
To avoid personal injury:
A
Do not remove radiator cap while coolant is
hot. When cool, slowly rotate cap to the first
stop and allow sufficient time for excess
pressure to escape before removing the cap
completely.
[M100GX, M110GX]
1. Stop the engine, remove the key and let it cool down.
2. To drain the coolant, open the radiator drain plug and
remove radiator cap. The radiator cap must be
removed to completely drain the coolant.
3. After all coolant is drained, reinstall the drain plug.
4. Fill with clean soft water and cooling system cleaner.
5. Follow directions of the cleaner instruction.
6. After flushing, fill with clean soft water and anti-freeze
until the coolant level is just below the radiator cap.
Install the radiator cap securely.
7. Fill with coolant up to the "FULL" mark of recovery
tank.
8. Start and operate the engine for few minutes.
9. Stop the engine, remove the key and let cool.
10. Check coolant level of recovery tank and add coolant
if necessary.
11. Properly dispose of used coolant.
Coolant capacity
9.6 L
(1) Drain plug ((+) Plus screwdriver)
Summary of Contents for M100GX
Page 17: ... 7 SAFE OPERATION 7 DANGER WARNING AND CAUTION LABELS ...
Page 18: ...SAFE OPERATION 8 ...
Page 19: ... 9 SAFE OPERATION ...
Page 20: ...SAFE OPERATION 10 ...
Page 21: ... 11 SAFE OPERATION ...