149
APPENDICES
*1: In the various setting mode, preset the "Working range of implement". (Refer to the "Initial Setting" in "SIDE DIGITAL
DISPLAY" in "OPERATING THE TRACTOR" section.) If not preset, correctly, incorrect data will be displayed.
Selected
screen
Info
Display
Remarks
Ref.
page
B
Work
area
A
Displays the work area measured from the
previous resetting.
A
Hold down the corresponding switch. The setting
goes back to "0.0".
A
(See *1.)
-
Selected
screen
Info
Display
Remarks
Ref.
page
C
Travel
distance
A
Displays the travel distance measured from the
previous resetting.
A
Hold down the corresponding switch, and the
setting goes back to “0”.
-
Loading
factor
Instantaneous loading factor
A
Each time the corresponding switch is pressed, the
“instantaneous”, “average” and “graph” are
displayed alternately in this order.
A
The “average” is measured based on the loading
factor from the previous resetting.
A
With the “average” displayed, hold down the
corresponding switch. The setting goes back to
“0”.
A
The “instantaneous loading factor graph”
graphically displays the instantaneous loading
factor in real time. (The more the bar is extended
to the right, the higher the load becomes.)
-
Average loading factor
-
Instantaneous loading factor graph
-
Clock
Time
A
Shows the standard factory settings. Refer to the
“Handling the side digital display” section.
42
Date
152
DPF
tempera-
ture
A
Displays the DPF muffler temperature.
14
PM
buildup
PM buildup
A
Displays the PM buildup inside the DPF muffler.
A
Regeneration is needed when the 100% level has
been reached.
A
Each time the corresponding switch is pressed, the
“numerical value” and “graph” are displayed
alternately.
A
The more the bar is extended to the right, the more
PM builds up.
14
PM buildup graph
14
Blank
A
Used to delete the information displayed.
-